Moxa MxNVR-IA8-T [9/61] 100 1000mbps ethernet port

Moxa MxNVR-IA8-T [9/61] 100 1000mbps ethernet port
Moxa MxNVR-IA8 Introduction
1-5
Off Hard disks are not connected
FAULT RED
On
3 conditions could cause the LED to light up:
Video source is loss
Network is disconnected
Hard disks are failed
Off No fault has occurred
V1 V2
V3 V4
V5 V6
V7 V8
GREEN
On Video source is in recording
Off Video source is not recording
LAN
AMBER
On 10/100 Mbps link is active
Blinking Data is being transmitted at 10 Mbps
Off 10/100 Mbps link is inactive
GREEN
On 1000 Mbps link is active
Blinking Data is being transmitted at 1000 Mbps
Off 1000 Mbps link is inactive
10/100/1000Mbps Ethernet Port
The MxNVR-IA8 has one RJ45 10/100/1000M Ethernet port (LEDs on the front panel will show the connection
to be 10/100M or 1000M).
RS-232/RS-422/RS-485 COM ports (reserved for future use)
Two RS-232/422/485 COM ports are located on the rear panel. The two COM ports are reserved for the future
use.
Pin RS-232 RS-422 RS-485 (4-wire) RS-485 (2-wire)
1 DCD TxDA(-) TxDA(-)
2 RxD TxDB(+) TxDB(+)
3 TxD RxDB(+) RxDB(+) DataB(+)
4 DTR RxDA(-) RxDA(-) DataB(-)
5 GND GND GND GND
6 DSR
7 RTS
8 CTS
24 VDC Power Input
The MxNVR-IA8 can be powered by a DC power input from 12 to 32 VDC. Users can check the PWR LED status
located on the front panel to see if the power inputs are connected appropriately.