Hama EWS-1300 Инструкция по эксплуатации онлайн [3/29] 172467

Install an anchor screw nail etc in the wall of your choice Hang up the base measuring station using the opening 19 31 intended for this purpose a a Slightly cloudy B Rain After the first time the base station is switched on the weather forecast symbol 1 will flash Press the C F button 22 or the AL ON OFF I button 23 to select the appropriate symbol for the current weather conditions Press the WEATHER button 20 to confirm your selections The base station forecasts the weather about 6 to 8 hours in advance If you change the height of the base station you must re enter the current weather status The height affects the weather forecast because the air pressure changes when the height does The weather forecast may not be exact if the correct symbol was not selected for the current weather conditions Snow Symbols The weather forecast is indicated by five different weather images 4 00123135man de_en _es_fr it pl _pt_ ru J n d d 4 5 The measuring range for humidity is between 20 and 99 If the current humidity falls below 20 will appear 3 If the humidity for the record display from the past 24 hours falls below 20 will appear 5 The snow forecast automatically appears if rain is forecast and outdoor temperature is below 0 C The symbol appears if the outdoor temperature is between 2 C and 3 C 6 2 Thermometer The base station automatically searches for a connection to the measuring station After the batteries are inserted correctly the measuring station transmits the temperature and humidity at the installation location If the base station does not receive a signal from the measuring station in the first 3 minutes press and hoIH the SEARCH button 18 for approx 3 seconds The symbol next to the OUT box will start to flash If no signal is received for an additional 3 minutes check the batteries polarity and the position of the measuring station Press the SEARCH button for approx 3 seconds to exit the search mode Temperature and humidity To change the current weather conditions press the WEATHER button 20 and hold it for approx 3 seconds until the symbol begins to flash Press the C F button 22 to choose between C and F on the temperature display If the temperature is outside of the measuring range LL L lower than minimum temperature or HH H higher than maximum temperature will appear on the temperature display If the alarm is tri outside tempera will sound Press the ALERT it will stop autom To deactivate the 15 repeatedly outside tempera 6 3 Time and ala Automatic settin After the first tim successful trans base station and automatically se the wireless sym Humidity 6 Base Station Startup and Operation 6 1 Weather forecast If you press the MEM button 16 again the date 12 time 8 and the saved value will begin to flash Press the MEM button 16 until the specific record value and the associated date and time begin to flash If a record value and the associated date and time appear and no other button is pressed the base station will return to the standard display after approx 15 seconds Hold the MEM button 16 for approx 3 seconds while the individual record is displayed to delete the current record Celsius Fahrenheit Cloudy IS Buy special or suitable installation material from a specialised dealer for wall mounting Ensure that no faulty or damaged parts are installed Never apply force during mounting This could damage the product After mounting the product check that it is sufficiently secure You should repeat this check at regular intervals If the mounting system is damaged take the product off the wall Before mounting the station ensure that the chosen wall is suitable for the weight to be mounted and make sure that there are no electrical wires water gas or other lines at the installation site on the wall Sun The base station automatically stores the maximum and minimum values for outside temperature and humidity These values 4 5 appear on the display for the past 24 hours Press the MEM button 16 to view the record of maximum and minimum values since the last start reset A Flashing display Outside temperature alarm function To set the alarm function press and hold the ALERT button 15 for approx 3 seconds The A symbol next to the outside temperature 2 will flash Press the C F button 22 or the AL ON OFF button 23 to select the upper alarm limit for the temperature Press the ALERT button 15 to confirm your selection The symbol next to the outside temperature 2 will start to flash Press the C F button 22 or the AL ON OFF button 23 to select the lower alarm limit for the temperature Press the ALERT button 15 to confirm your selection Press the ALERT button 15 until the A symbol next to the outside temperature 2 is displayed The alarm is triggered as soon as the outside temperature reaches or exceeds the upper limit selected If you press the ALERT button 15 again the symbol next to the outside temperature 2 is displayed The alarm is now triggered as soon as the outside temperature reaches or exceeds the upper limit or reaches or falls below the lower limit If you press the ALERT button 15 again the symbol next to the outside temperature 2 is displayed The alarm is now triggered as soon as the outside temperature reaches or falls below the lower limit selected Constant display No display The clock automa day at 3 00 AM t search fails it en The wireless sym If the station sti the C F b AL ON OFF the manual sear 10 will start to