Hotpoint-Ariston HGF 6.8 AD X/HA [37/84] Maintenance and care

Hotpoint-Ariston HGF 6.8 AD X/HA [37/84] Maintenance and care
GB
37
Grease/odour lter warnings
The bar at the top left ashes to indicate
that the grease lter is saturated.
The bar at the top right ashes to indicate
that the odour lter is saturated.
If both bars are ashing, then both lters
are saturated.
You must then clean/replace the grease lter (A) or odour
lter (B) or both, accordingly (see “Maintenance and care”).
The latter only applies to the lter version.
To reset the lter counter:
Hold down T4 for three seconds while the hood is on.
If both lter warnings are active at the same time, you must
reset each separately. The rst sequence resets the grease
lter, while the second sequence resets the odour lter.
Con guring the hood
To set the operating mode of the hood, hold down T4 for
6 seconds,while the product is off. After a long beep, the
type of installation displays:
Ducted
(square at bottom left ashing).
Filter
(square at bottom right ashing).
You can change the type of installation by pressing T4. To
quit con guration mode, press T1 once; this switches the
unit off and saves the last displayed setting.
Maintenance and care
Caution! Before cleaning or servicing the unit,
disconnect it from the mains by pulling the power plug
or disconnecting the main circuit breaker.
First cleaning
Remove the protective lm
Clean with a damp sponge and a little neutral soap
Rinse off with a damp cloth
Dry with a soft cloth; if the hood is stainless steel, dry
along the metal's grain
Periodic cleaning
The hood must be cleaned frequently (at least as often as
you service the grease lter), inside and out. Use a damp
cloth and a neutral liquid detergent with lukewarm water.
Do not use abrasive or corrosive products.
Warning: Failure to observe the hood cleaning and lter
cleaning/replacement instructions can result in res. Follow
the instructions carefully. The manufacturer is not liable for
any damage to the motor or res caused by incorrect care
or failure to follow the above instructions.
Servicing the grease lter (A)
A
The grease lter retains the
particles of grease produced
during cooking; it must be
cleaned at least once a month
with a non-aggressive
detergent, either by hand or
with a low temperature, short
dishwasher cycle.
To extract the grease lter,
pull the spring loaded handle.
If washed in a dishwasher, the metal lter may change
colour, but this does not affect its performance.
Servicing the charcoal lter (B)
The charcoal lter retains unpleasant cooking odours.
The lter saturates after a variable time, depending on the
type of cooking and how often the grease lter is cleaned.
The cartridge must be replaced at least once every twenty
months.
This lter can NOT be washed or regenerated
B
Disassembly: Remove the
activated-carbon filter by
pressing the two front levers
which secure it to the hood.
B
Assembly: Secure the
activated-carbon lter rst in
the back using the hood's
metal tabs and then in the
front by pressing the two
levers.

Содержание

Похожие устройства

Скачать