Installation
The installation procedure is illustrated in the rst pages
of this manual.
The installation must be done by a qualied technician.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
socket is not easily accessible, install a two-pole regulatory
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution! Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust (for ducted units)
Connect the hood to a duct and wall exhaust hole of a
diameter equal to that of the air outlet ange. Using a smaller
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
! Use the shortest duct required to achieve the purpose.
! Use a duct with as few bends as possible
! Avoid suddenly changing the diameter of the duct.
! The duct must have as smooth an inner surface as
possible.
! The duct must be made of regulatory material.
! Do not connect the hood to ues carrying combustion
fumes from other equipment (boilers, chimneys, stoves,
etc.).
! Observe the instructions of the competent authorities in
relation to the air exhaust. The air being exhausted may not
be exhausted into a wall cavity unless the cavity in question
is specically intended for this purpose.
! Equip the room with air intakes to prevent the hood creating
suction pressure in the interior (this must not exceed 0.04
mbar).
! The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
! Your hood is supplied as a ducted unit.
If you wish to use it as a lter unit, you must install the proper
ACCESSORY KIT.
Note: If supplied with the hood, the accessory active
charcoal lter unit may already be installed.
Instructions for transforming the hood from the ducted to the
lter version are given in this manual (see “Filter version”).
Ducted version
The hood puries the air and expels it outdoors via an exhaust
duct (dia. 150mm) connected to its outlet ange. The diameter
of the exhaust tube must be equal to that of the outlet ange.
Caution! The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
outdoors more easily. If the hood is tted with charcoal
lters, they must rst be removed.
Filter version
The hood puries the air and returns it to the room. This
version of the hood requires installation of an accessory
active charcoal lter unit.
This version requires an air deector, a reduction adapter
and the charcoal lter/s. The top tube must have its air
outlet slots uppermost.
Technical data
Model
Height
(cm)
Width
(cm)
Depth
(cm)
dia. of
exhaust tube
(cm)
PYRAMID 60cm 61-82 59.8 50 15/12
PYRAMID 70cm 61-82 69.8 50 15/12
PYRAMID 90cm 61-82 89.9 50 15/12
Model code Bulb (V) Bulb draw (W) Total draw (W)
HNP 6.5 CM X/HA
HYM 60 IX/HA
HPM 61 IX/HA
7HHP 6 R (OW)/HA
7HHP 6 R AN/HA
HRP 6.5 CM (OW)/HA
HRP 6.5 CM (AN)/HA
Halogen 2 x 25 160
Model code Bulb (V) Bulb draw (W) Total draw (W)
HNP 6.5S CD X/HA
HPS 60 IX/HA
HRP 6.5S CM (OW)/HA
HRP 6.5S CM (AN)/HA
Halogen 2 x 25 195
Model code Bulb (V) Bulb draw (W) Total draw (W)
HNP 6.6 AM W/HA
HNP 9.6 AM W/HA
HNP 9.6 AM K/HA
HNP 9.6 AB X/HA
HNP 9.6 AM X/HA
HNP 6.6 AM K/HA
HNP 6.6 AM X/HA
Halogen 2 x 20 210
HRP 9.6 CM (OW)/HA Halogen 2 x 25 220
Model code Bulb (V) Bulb draw (W) Total draw (W)
HRP 9.8 CM (OW)/HA
HRP 9.8 CM (AN)/HA
Halogen 2 x 25 300