Aten CS1922 [30/51] Keyboard operating platform

Aten CS1922 [30/51] Keyboard operating platform
CS1922 / CS1924 User Manual
22
Keyboard Operating Platform
The CS1922 / CS1924’s default port configuration is for a PC-compatible
keyboard operating platform. If your console uses a PC-compatible keyboard
and you have a Mac attached to a port, for example, you can change the port’s
keyboard operating platform configuration so that the PC-compatible keyboard
emulates the Mac keyboard. The procedure is as follows:
1. Bring the KVM focus to the port you want to set.
2. Invoke HSM (see page 20).
3. Press and release the appropriate Function key (see table below). After
completing this procedure, you automatically exit HSM.
List Switch Settings
To see a listing of the current switch settings, do the following:
1. Open a text editor or word processor and place the cursor in the page
window.
2. Invoke HSM (see page 20).
3. Press and release [F4] to display the settings.
USB Reset
If the USB loses focus and needs to be reset, do the following:
1. Invoke HSM (see page 20 for details).
2. Press and release [F5].
Function Key Operation
[F1]
To set the keyboard/mouse to use SPC mode so that it
can work under special operating systems as a standard
(104 key) keyboard/mouse.
[F2]
Enables Mac keyboard emulation, see Mac Keyboard,
page 27 for details.
[F10] Automatically detects and sets the keyboard operating
platform.