IBM system x3530 m4 (7160k2g, 90y8826 х4, 49y3760, 00d4413) Инструкция по эксплуатации онлайн [23/402] 183097

IBM system x3530 m4 (7160k2g, 90y8826 х4, 49y3760, 00d4413) Инструкция по эксплуатации онлайн [23/402] 183097
Table 1. Server features and specifications (continued)
RAID controllers:
The following RAID options are
available for the server:
v ServeRAID H1110 SAS/SATA
Controller for System x
v ServeRAID M1115 SAS/SATA
Controller for System x
v ServeRAID M5110 SAS/SATA
Controller for IBM System x
v ServeRAID M5120 SAS/SATA
Controller for IBM System x
v ServeRAID M5100 Series Battery
Kit for IBM System x
v ServeRAID M5100 Series 512MB
Cache/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series 512MB
Flash/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series Zero
Cache/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series 1GB
Flash/RAID Upgrade for IBM
System x
v ServeRAID C105 for IBM System X
Size:
v Height: 43 mm ( 1.7 inches, 1U)
v Depth: 673.1 mm (26.5 inches)
v Width: 447 mm (17.6 inches)
v Maximum weight: 15.8 kg (33.8 lb)
when fully configured
Acoustical noise emissions:
v Sound power, idling: 6.5 bels
v Sound power, operating: 6.5 bels
Environment:
v Air temperature:
Server on: 5°C to 40°C (41°F to
104°F); altitude: 0 to 915 m (3000
ft)
Server on: 5°C to 32°C (41°F to
89.6°F); altitude: 915 m (3000 ft)
to 2134 m (7000 ft)
Server on: 5°C to 28°C (41°F to
82.4°F); altitude: 2134 m (7000
ft) to 3050 m (10000 ft)
Server off: 5°C to 45°C (41° to
113°F)
Shipment: -40°C to +60°C (-40°F
to 140°F)
v Humidity:
Server on: 8% to 85%; maximum
dew point: 24°C (75.2°F);
maximum rate of change 5
°C/hr
Server off: 8% to 80%; maximum
dew point: 27°C (80°F)
Shipment: 5% to 100%
v Design to ASHRAE Class A3:
Ambient of 35°C to 40°C (95°F
to 104°F), with relaxed support
Support cloud like workload
with no performance
degradation acceptable
(Turbo-Off)
Under no circumstance, can any
combination of worst case
workload and configuration
result in system shutdown or
design exposure at 40°C (104°F)
v Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
“Particulate contamination” on
page 373.
Heat output:
Approximate heat output:
v Minimum configuration: 406 Btu
per hour (119 watts)
v Maximum configuration: 2627.3
Btu per hour (770 watts)
Electrical input:
v Sine-wave input (50 - 60 Hz)
required
v Input voltage automatically
selected
v Input voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
v Input voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
Minimum: 0.12 kVA
Maximum: 0.78 kVA
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
2. The noise emission level stated is
the declared (upper limit) sound
power level, in bels, for a random
sample of machines. All
measurements are made in
accordance with ISO 7779 and
reported in conformance with ISO
9296.
Chapter 1. The IBM System x3530 M4 Type 7160 server 7