Chapter 5: Advanced Serverboard Setup
5-235-22
SUPERSERVER 6028R-TR/TRT User's Manual
I
2
C to PCI-E Slots
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled
Pins 2-3 Disabled
I
2
C Bus to PCI-Exp. Slots
Jumpers JI
2
C1 and JI
2
C2 allow you to
connect the System Management Bus
(I
2
C) to the PCI-Express slots. The
default setting is disabled. Both jump-
ers must be set to the same setting
See the table on the right for jumper
settings.
BMC Enable
Jumper JPB1 allows you to enable
the embedded Winbond BMC (Base-
board Management Controller) to
provide IPMI 2.0/KVM support on the
serverboard. See the table on the right
for jumper settings.
BMC Enable
Jumper Settings
Jumper Setting Denition
Pins 1-2 BMC Enabled
Pins 2-3 Disabled
Manufacturer Mode Select
Close pins 2 and 3 of jumper JPME2
to bypass SPI ash security and force
the system to operate in the Manufac-
turer Mode, which allows the user to
ash the system rmware from a host
server for system setting modications.
See the table on the right for jumper
settings.
ME Mode Select
Jumper Settings
Jumper Setting Denition
Pins 1-2 Normal (Default)
Pins 2-3 Manufacture Mode
BIOS Recovery Jumper
Settings
Both Jumpers Denition
Pins 1-2 Enabled
Pins 2-3 Normal
BIOS Recovery Enable (JBR1)
Close pins 1 and 2 of jumper JBR1 for
BIOS recovery. The default setting is
on pins 2 and 3 for normal operation.
See the table on the right for jumper
settings.
5-10 Onboard Indicators
LAN LEDs
The Ethernet ports (located beside the
VGA port) have two LEDs. On each
port, one LED ashes to indicate activ-
ity while the other LED may be green,
amber or off to indicate the speed of
the connection. See the table on the
right for the functions associated with
the connection speed LED.
JLAN1/2 LED
(Connection Speed Indicator)
LED Color Denition
Off 10 Mb/s, 100 Mb/s or no
connection
Green 10 Gb/s (X10DRi-T only)
Amber 1 Gb/s
Onboard Power LED
An Onboard Power LED is located at
LE2. This LED Indicator is lit when
the system is on. Be sure to unplug
the power cable before removing or
adding any components. See the table
on the right for more details.
IPMI Dedicated LAN LEDs
An additional Dedicated IPMI LAN is
also located on the I/O backplane.
The amber LED on the right indicates
activity, while the green LED on the
left indicates the speed of the connec-
tion. See the table at right for more
information.
IPMI LAN Link LED (Left) &
Activity LED (Right)
LED Status Denition
Link (Left) Green: Solid 100 Mb/s
Activity (Right) Amber: Blinking Active
X8DT3-LN4/LN4F
X8DT3/i-F/-LN4F
Link LED
Activity LED
IPMI LAN
BMC Heartbeat LED
A BMC Heartbeat LED is located at
LEDM1 on the serverboard. When
D1 is blinking, BMC is functioning
normally.
Onboard PWR LED Indicator
LED Settings
LED Color Status
Off System Off (PWR cable
not connected)
Green System On
BMC Heartbeat LED
Status
Color/State Denition
Green:
Blinking
BMC: Normal