Dometic MSI 924 [18/432] Connecting the inverter

Dometic MSI1824T [18/432] Connecting the inverter
EN
Connecting the inverter SinePower
18
8.3 Mounting the inverter
Hold the inverter against the installation location and mark the fastening points
(fig. 4 A, page 4).
Attach the inverter using your chosen fastening method (fig. 4 B, page 4).
9 Connecting the inverter
9.1 General instructions
!
When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
When setting up a socket distribution circuit (mains setup), comply with the appli-
cable regulations.
Only use copper cables.
Keep the cables as short as possible (< 1.8 m).
WARNING!
The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
Reversed polarity can damage the inverter.
MSI900, MSI1300, MSI1800 only: The inverter should not be
used to connect to a ring main, it must only be used to power individ-
ual appliances that are plugged into the inverter outlet either directly
or using a purpose-made, moulded extension lead
MSI900-1800--IO-16s.book Seite 18 Montag, 15. August 2016 1:50 13