Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches. In this
way, the battery you connect to the inverter is not discharged as quickly.
The inverter operates in energy-saving mode as long as the required power is below
the set level. If the required power exceeds the set level, the inverter works in normal
mode.
The values to be set on your inverter can be found in the following table:
Defining settings
Using the S8 dip switch you can define whether the default settings or the settings of
dip switches S1 – S7 are used.
Default settings
Energy-saving mode Dip switch
MSI900 MSI1300 MSI1800 S4 S5 S6
Off Off Off Off Off Off
60 – 120 W 110 – 190 W On Off Off
70 – 110 W 130 – 170 W 190 – 240 W On On Off
180 – 240 W 180 – 240 W 240 – 300 W On On On
Dip switch
Parameter S8
Default settings On
Use dip switch S1 – S7 Off
Mains voltage Net frequency Energy-saving mode
230 V 50 Hz Off