Bosch BSG61800 [14/101] Changing the dust bag

Содержание

en EQ Figure You can use the parking aid on the side of the vacuum cleaner if you wish to stop vacuuming for a short time Once you have switched off the vacuum cleaner slide the catch on the floor tool into the groove on the side of the appliance EQ Figure The appliance can also be carried using one of the two handles when vacuuming steps for example When the work is done EQ Figure Unplug the vacuum cleaner Tug the power cord briefly and let go The cable then rewinds automatically EQ Figure To store or transport the vacuum cleaner use the storage aid on the underside of the vacuum cleaner Stand the vacuum cleaner up on Its end Slide the catch on the floor tool Into the groove on the underside of the appliance Changing the dust bag Clean the motor protection filter by tapping it If it is very dirty the motor protection filter should be rinsed The filter must then be left to dry for at least 24 hours After cleaning slide the motor protection filter into the vacuum cleaner and close the dust bag compartment lid Replacing the micro hygiene filter The motor protection filter should be changed when starting a newpack of bags EiJ Figure Open the dust bag compartment lid see Figure 20 Release the filter holder by moving the locking lever in the direction of the arrow Remove the micro hygiene filter Insert the new micro hygiene filter Into the vacuum cleaner Reinsert the filter holder and clip into place Replacing the micro active carbon filter If your vacuum cleaner Is equipped with a micro active carbon filter this should be replaced every six months SI Figure Open the dust bag compartment lid see Figure 20 Release the filter holder by moving the locking lever in the direction of the arrow Remove the micro active carbon filter Insert the new micro active carbon filter Reinsert the filter holder and clip into place Replacing the dust bag DS Figure a If the dust bag change indicator Is completely yellow when the floor tool Is lifted from the floor and the highest suction power is selected the dust bag must be changed In this case it Is essential to change the dust bag due to the type of material It contains The nozzle suction pipe and flexible tube must not be blocked as this would also cause the dust bag change Indicator to be triggered b The handle can easily be detached from the hose to remove blockages EQ Figure Open the lid by moving the locking lever In the direction of the arrow SI Replacing the Hepa filter If your vacuum cleaner Is equipped with a Hepa filter this should be replaced once a year Eiil Figure Open the dust bag compartment lid see Figure 20 Release the Hepa filter by moving the locking lever In the direction of the arrow and remove it from the vacuum cleaner Insert the new Hepa filter and dip Into place If you have used the vacuum cleaner for fine dust particles dean the motor protection filter and If necessary replace the micro active carbon filter or Hepa filter Care Figure a Seal the dust bag by pulling the sealing strip and then remove it b Slide the new dust bag into the holder to the stop Always switch off the vacuum cleaner and disconnect the power cord from the mains before cleaning the appliance The vacuum cleaner and plastic accessories can be cleaned with a commercial plastic cleaner Caution The lid only closes with a dust bag inserted Cleaning the motor protection filter The motor protection filter should be cleaned regularly by knocking out the dirt and rinsing Do not use a scourer glass cleaning agent or all purpose cleaning product Never immerse the vacuum cleaner in water Figure E3 Open the dust bag compartment lid see Figure 20 Pull out the motor protection filter in the direction of the arrow The dust compartment can If necessary be cleaned with a second vacuum cleaner or simply wiped with a a dry cloth or dusting brush Subject to technical modifications 9

Скачать