Kitano KC-Montaro II-48 [31/68] Specifications

Kitano KC-Montaro II-60 [31/68] Specifications
Model
KC-Montaro II
-18
KC-Montaro II
-24
KC-Montaro II
-36
Capacity
cooling W 5300 7500 10800
heating W 5900 8200 12500
Power input
cooling W 1649 2371 3593
heating W 1735 2192 3409
EER W/W 3.21 3.16 3.01
COP W/W 3.40 3.74 3.67
Air flow m
3
/h 800 1400 1700
INDOOR UNIT
KC-Montaro II
-18/I
KC-Montaro II
-24/I
KC-Montaro II
-36/I
Power supply ph/V/Hz 1 / 220–240 / 50
Noise level dB(А) 34/38/41 37/41/43 41/43/45
Drain pipe diameter mm 32 32 32
Unit dimension (WxHxD) mm 575×575×260 830×830×230 830×830×290
Unit package dimension (WxHxD) mm 725×725×300 950×950×250 950×950×320
Unit weight (net/gross) kg 18.5/22.6 24/29.2 30/35.5
Panel dimension (WxHxD) mm 650×30×650 950×45×950 950×45×950
Panel package dimension (WxHxD) mm 760×100×760 1035×90×1035 1035×90×1035
Panel weight (net/gross) kg 2.5/4.5 5.9/8.3 5.9/8.3
OUTDOOR UNIT
KC II-18/O KC II-24/O KC II-36/O
Power supply ph/V/Hz 1/220–240/50 3/380–415/50
Noise level dB(А) 49/52 51/54 55/58
Dimension (WxHxD) mm 780×290×605 900×310×650 900×805×360
Package dimension (WxHxD) mm 883×412×653 1015×425×720 1031×835×447
Weight (net/gross) kg 38/42 51/55 78/87
REFRIGERANT PIPES
Refrigerant type
R410A
Refrigerant charge kg
1.5 2.0 2.1
Max. refrigerant pipe length m
25 30 30
Max. height difference
m
15 15 20
Diameter
liquid mm 6.35 9.52
12.7
gas mm 12.70 15.88
19.05
3. SPECIFICATIONS
Nominal capacities are based on the following conditions:
— cooling: indoor temp. 27 °С (DB)/19 °C (WB), outdoor temp. 35 °С (DB)/24 °C (WB)
— heating: indoor temp. 20 °С (DB)/15 °C (WB), outdoor temp. 7 °С (DB)/6 °C (WB)