Kitano KC-Montaro II-48 [52/68] Cassette type air conditioners montaro ii series

Kitano KC-Montaro II-48 [52/68] Cassette type air conditioners montaro ii series
50
cassette type air conditioners, Montaro II series
Model KC-Montaro II-18 KC-Montaro II-24
Power supply ph/V/Hz
1/220-240/50 (indoor unit)
1/220-240/50 (outdoor unit)
Min/max voltage V
198/254 (indoor unit)
198/254 (outdoor unit)
Outdoor unit power
wiring
n
xmm
2
3×2.5 3×2.5
Indoor unit power wiring n
xmm
2
3×2.5 3×2.5
Signal wiring n
xmm
2
4×1.5+2×0.75 4×1.5+2×0.75
Table 7.4.1.
Model KC-Montaro II-36 KC-Montaro II-48 KC-Montaro II-60
Power supply ph/V/Hz
1/220-240/50 (indoor unit)
3/380/50 (outdoor unit)
Min/max voltage В
198/254 (indoor unit)
342/418 (outdoor unit)
Outdoor unit power
wiring
n
xmm
2
5×2.5 5×2.5 5×2.5
Indoor unit power wiring n
xmm
2
3×2.5 3×2.5 3×2.5
Signal wiring n
xmm
2
4×1.5+2×0.75 4×1.5+2×0.75 4×1.5+2×0.75