Castel MAC TC 60 N [5/17] Installation
![Castel MAC TC 60 N [5/17] Installation](/views2/1318629/page5/bg5.png)
2.1 Data plate information
• Check that the data specified on the
plate correspond to the characteristics of
the power supply (V,
kW, Hz, no. phases
and power available)
• The data plate
with appliance specifi-
cations is located at the
rear exterior of the machine and/or on the
electrical control boxes. Any preparation
of individual appliances for the positioning
of condensing units must comply with the
current fire-prevention regulations in the
country of installation (see the local fire
department for the necessary details).
Bear in mind that any intervention of safe-
ty valves or fuse plugs in the refrigerating
circuit will lead to the immediate dis-
charge of refrigerant into the environment.
2.2 Positioning
• The appliance must be installed and
commissioned in full compliance with
safety regulations, procedures and cur-
rent laws
• The installer must ensure compliance
with any fire-prevention provisions (see
the local fire department for the neces-
sary details).
• Position the appliance in the allocated
site
• Adjust the feet until the appliance is per-
fectly level. For levelling heavy applian-
ces, use appropriate lifting means
WW
WW
AA
AA
RR
RR
NN
NN
II
II
NN
NN
GG
GG
!!
!!
!!
!!
!!
!!
THESE OPERATIONS MUST BE ONLY
PERFORMED BY A
LICENSED INSTALLER
2. INSTALLATION
5
GB
surfaces (fig. 2)
•
Always wear protective gloves when
handling packing material and the
wood base.
• NB: Dispose of packing materials in com-
pliance with current regulations in the
country where the appliance is installed.
Do not disperse materials in the environ-
ment.
1.5 General safety regulations
The user is fully responsible in case of any
operations carried out on the appliance
and not in compliance with the instructions
given in this manual. The main safety reg-
ulations are as follows:
-
do not touch the appliance with moist
or wet hands or feet - do not operate
on the appliance when barefoot;
- do not insert screwdrivers, kitchen
utensils or any other object between
the guards and moving parts
- before performing cleaning or routine
maintenance operations, disconnect
the machine from the power supply by
operating the main switch, also
disconnecting the main knife switch
(if present)
- do not pull the power cable to discon-
nect the appliance from the power
supply
Содержание
- Instruction manual 1
- Preservation cabinets 1
- Tecnocontrol 1
- General documentation 4
- Installation 5
- Thecnical characteristics 8
- Programming instruction 9
- Defrost management 11
- Managing and silencing detected alarms 12
- Al 26 black out b 15 03 02 10 22 13
- Al 26 black out max temp 12 c 13
- Al 26 black out s 15 03 02 10 01 13
- Alarm detected cell 24 0 c 13
- Example of power failure blackout alarm 13
- Fault messages 13
- Important 13
- In the case of high low temperature alarms a pre alarm time of 60 minutes is counted before they are stored when this time has elapsed the controller records the alarm in the alarms list and shows the follow ing message on the display 13
- In the event of a serious alarm contact the authorised tecnomac service centre 13
- Message display cause cancellation 13
- Serious alarms list serious alarms can cause the preservation unit to function incorrectly they are displayed in the same way as the other alarms and the buzzer is activated to silence the buzzer press enter cancellation occurs automatically when the fault is eliminated but the alarm is still stored in the alarms menu 13
- To cancel this indication enter the alarms list as described in the previous paragraph 13
- Alarm detected continuous alarm recorded eliminate the cause in the memory of the alarm and enter menu 1 to reset the controller alarms list 14
- Ht continuous high temperature pre alarm automatic cancellation 14
- List of other operating faults not indicated 14
- Lt continuous low temperature pre alarm automatic cancellation 14
- Set clock loss of clock data set clock data 14
- Warning messages they do not compromise appliance operation message display cause cancellation 14
- Routine maintenance 15
Похожие устройства
- Castel MAC HC 20 BT Инструкция по эксплуатации
- Castel MAC HC 20 NTB Инструкция по эксплуатации
- Steno PL7B Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Сертификат
- ТОРГМАШ УКМ-14 Каталог оборудования ТОРГМАШ
- Pavoni MINITEMPER Инструкция по эксплуатации
- Pavoni MINITEMPER Каталог оборудования Pavoni (англ.)
- Castel MAC HC 20 C Инструкция по эксплуатации
- Talsa Н26pa Инструкция по эксплуатации
- Talsa H42pas Инструкция по эксплуатации
- Talsa Н31pas Инструкция по эксплуатации
- Talsa Н15pa Инструкция по эксплуатации
- Helia Smoker 48 Инструкция по эксплуатации
- Helia Smoker 48 Рецепты копчения
- Helia Smoker 24 Инструкция по эксплуатации
- Helia Smoker 24 Рецепты копчения
- CAS CNW-460 Инструкция по эксплуатации
- CAS СNW-520 Инструкция по эксплуатации
- JEJU JDZ-260/PD Инструкция по эксплуатации