Polaris ORION S 5.5 (душ) [17/21] Technical service regulation

17
should be made in the following way : there is a switch under the cover, at the bottom part of
which there is a rectangle with an open side. It is necessary to turn it upwards. There is a pin
in the base. There is a skew lever, one side of which is larger than the other. Please turn the
larger side upwards. After that, please put the cover on the base.
9. It is forbidden to input the water with temperature above 35
o
C; it may cause the overheating
of outlet water to level above 95
o
C.
ATTENTION PLEASE! It is forbidden to switch on the appliance when there is a
danger for the freezing of the water in the water heater.
The order of working
The flow-type water heater works automatically. For the working of the water heater it is
recommended to have a pressure not less than 25000 Pa and the output flow of water not less
than 1,5 liters per minute. The maximum working pressure is 600000 Pa. The water heater
switches on automatically when the tap on the water inlet is open and the power selector is in
ON position.
Before the beginning of working it is necessary to open the water flow with the help of the tap on
the water inlet and turn on the power selector (light signals will appear over it).
Power selector:
0 no heating,
1 - minimum heating level,
2 medium heating level,
3 maximum heating level
To switch the heater off it is necessary to set the power selector in OFF position (light signals
will die out) and to close the tap.
Technical service regulation.
In the durative process of exploitation , when the warranty period is over, it is necessary to make
routine repairs once or twice a year.
- Turn the water heater off the main electrical supply
- Examine the water heater carefully , clean the water heater with the duster, check the water
pipes, remove the corrosion (if it is necessary to blow off) and cover with the layer of protective
lubrication.
ATTENTION!
Be careful! There mustnt be any obstructions in the water outlet hose and shower- head.
- clean the injectors of the shower-head
- make the shifting of the screwed connections.
If the hydraulic drop (water flow) become worse, you should clean the rings of the water heater
and a strain (filter) which is set up at the inlet of the water heater.
Trouble shooting
The functioning of the heater can be tested after installation as followsturn it on and press the
"supply choice button" for maximum heat, with the shower head also set for Winter (few "holes"
open for maximum heat). Now, set the water flow to minimum. The heater is working well if the
water becomes hot.