Brita PURITY 1200 Clean [17/90] Commissioning a new filter

Brita PURITY 1200 Clean [17/90] Commissioning a new filter
5 Commissioning a New Filter
5.1 Setting the Bypass
The bypass setting screw
13
has been set to 0% at the factory and, if necessary, can
be increased to 10% according to the local water quality or application in question.
If you have any questions about water quality, your supplier or your contact at BRITA
will advise you.
Note: Use Allen key 6mm or 7/32" to adjust the bypass setting screw
13
.
5.2 Identifying the Filter Capacity
Identify the local carbonate hardness or total hardness using the enclosed carbonate
hardness or total hardness test kit.
Identify the fi lter capacity using the capacity tables (Chapter 7) taking account of the
carbonate or total hardness identi ed and the bypass setting (Chapter 5.1).
5.3 Flushing and Bleeding the Filter Cartridge
Note: A bucket with a minimum capacity of 10L is needed for fl ushing/bleeding.
,
Place the bucket under the fl ush hose and open the fl ush valve
16
.
Open the inlet valve
6
on inlet hose
5
while holding the fl ush hose
in the bucket. Flush with at least 10 litres.
Close the fl ush valve
16
and empty the bucket.
Check system for any leaks.
Note installation date of the fi lter system on pressure vessel
1
and
next exchange date on the enclosed sticker (PURITY 1200 Clean:
light blue sticker, PURITY 1200 Clean Extra: red sticker) and attach it
to the Service Pass on the pressure vessel
1
.
6 Exchanging the Filter Cartridge
The fi lter cartridge must be replaced after 612 months, at the latest 12 months after
commissioning, irrespective of the level of exhaustion of the fi lter system. If the capacity
of the fi lter cartridge has been exhausted (Chapter 7), it must be replaced earlier.
!
Caution: During the exchange, carefully examine all dismantled parts! Faulty parts
must be exchanged, dirty parts cleaned! Read the operating and safety information
(Chapter 3) prior to replacement. After the product has been stored at temperatures
below 0 °C, it must be stored with the original packaging open at the ambient temperature
of the place of installation for at least 24 hours before entering use.