Brita PURITY 1200 Steam без дисплея [25/162] Commissioning a new filter

Brita PURITY 1200 Steam без дисплея [25/162] Commissioning a new filter
23
1 x Filter Cartridge
2
1 x Manual
1 x Carbonate Hardness Test
1 x Sticker for Service Pass (orange)
1 x Adapter 1"–3/4"
If parts of the delivery scope are missing, please contact your local BRITA offi ce (see the back of the
cover).
4.2 Assembling the Pressure Vessel and the Pressure Vessel Lid
Stand with both feet on the kick loops
12
.
Lift the pressure vessel
1
and turn it clockwise until the mantle handles
16
are over the kick loops
12
.
Remove the transport protective cap
18
from the fi lter cartridge.
Check that the O-ring seal of the fi lter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: lubricant at the factory.
Stand on the kick loops
12
with both feet and place the pressure vessel lid
3
on the pressure vessel
1
. The position of the arrow marking on the lid
handle
20
must match the “INSERT” groove.
Press the pressure vessel lid
3
down and turn clockwise until the lock
15
engages.
4.3 Assembly of Inlet and Outlet Hoses
Note: The inlet and outlet hoses are not included in the standard scope of delivery. The use of
BRITA hose sets is recommended (Chapter 13).
Fit inlet hose
6
at the inlet of the connector head
4
and outlet hose
10
at the outlet of the con-
nector head
4
.
Note: Inlet “IN” and outlet “OUT” of the connector head
4
are equipped with O-rings as
seals, therefore no additional fl at seals may be used here. Check that the O-rings are seated
correctly.
!
Caution: The max. tightening torque at the 1" and 3/4" connections must not exceed 15 Nm!
Only hose connections with fl at seals may be used. Hoses with conical screwed connections dam-
age the fi lter head connections and invalidate any guarantee claims. Only hoses that comply with
DVGW-W 543 may be used to connect the device.
Before assembly, note the direction of fl ow on the upper side of the fi lter head, “IN” = water inlet,
“OUT” = water outlet. Prior to installation, note installation dimensions and operating position
(Chapter 12). If no original hoses are used, the 1"3/4"
17
adapter supplied must be used to ensure
the return valve is sealed correctly (pre-fi tted in the water inlet).
5 Commissioning a New Filter
5.1 Bypass Setting for Filter Systems without and with Measuring and Display Unit
Identify the local carbonate hardness in German hardness °dH (BRITA nomenclature °KH) using
the enclosed carbonate hardness test.
Check the bypass setting on the bypass screw
19
.
Note: The bypass has been set to Position 1 in the factory, and must be changed to suit the
local carbonate hardness and the application (Chapter 7).