Program Overview
ID-Information
ÀÀÀ
00 Current level
ÀÀÀ
-1 History level 1
ÀÀÀ
-2 History level 2
ÀÀÀ
-3 History level 3
ÀÀÀ
-4 History level 4
ÀÀÀ
E1 Error inlet metre
ÀÀÀ
E2 Error drainage metre
Filter system type and size 2 sec.
ÀÀÀ
Type of hardness (unit)
and value 2 sec.
ÀÀÀ
Monthly limit 2 sec.
ÀÀÀ
RESET 2 sec.
ÀÀÀ
Parameter acceptance
Operating mode
ParameterisationRetrieval mode
1 x button Press button 4 seconds
30 sec.no activity =
no Parameter acceptance
20 sec. no activity
Carbonate hardness • Ca-
pacity • By-pass • last fi lter
change date
10 Troubleshooting
10.1 No water fl ow
Cause: Water intake closed.
Troubleshooting: Open water intake on the upstream stop valve or inlet valve
7
on inlet hose
6
.
!
Caution: The following faults may be remedied only by trained and authorised personnel.
10.2 No or low water fl ow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure.
If the fault continues in spite of adequate mains pressure, check the fi lter
system and fi lter cartridge and change if necessary.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the
Operating and Safety Information (Chapter 3).