Press the button once (> 2 seconds) until the total
capacity (at 0% bypass) and the current date appear.
> 2 sec
The set parameters have been accepted.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on
the display part must be inserted in the grooves on the measuring head. Continue with Chapter
5.4 Flushing/Draining for Filter Systems with and without Measuring and Display Unit.
5.3 Bypass Setting
Determining the bypass setting
The bypass setting is identi ed according to the application and the carbonate hardness identi ed
on the basis of the bypass and capacity table (Chapter 7). The bypass is then set on the bypass
screw
19
as follows:
Turn the bypass screw
19
until the desired bypass (03) agrees with the marking.
!
Caution: Use 6 mm or 7/32" Allen key.
!
Note: Never overwind the by-pass screw to avoid any damage.
5.4 Flushing/Bleeding Filter Systems with and without Measuring and Display Unit
Note: A 10 litre bucket is required for fl ushing/draining.
Position fi lter system horizontally.
Completely open fl ush valve
9
.
Fully open the inlet valve
7
at inlet hose
6
while holding the fl ush hose in
the bucket. Flush with at least 10 litres of water with a minimum volumetric
ow of 3 l/min (180 l/h).
Close fl ush valve
9
, put down fi lter and empty bucket.
Carefully open fl ush valve
9
while holding the fl ush hose in the bucket.
Flush quantity once again with at least 10 litres.
Close fl ush valve
9
.
Check system for any leaks.
Note installation date of the fi lter system and the next exchange date on the enclosed sticker
and attach it to the pressure vessel.