Chigo CS/CU-25H3A-V84 Коды ошибок онлайн [7/13] 275319

Chigo CS/CU-25H3A-V84 Коды ошибок онлайн [7/13] 275319
7
3 When the 1 and 2 are both normal, then the components or integrated
circuit is damaged, the electric control board should be replaced.
continuous
lamp flicker
4times
temp. sensor and
humidity sensor
all fault
1Check whether the resistance of the temperature sensor is normal,
otherwise replace it.
2Check whether the humidity sensor is normal, otherwise replace it.
water full lamp
flicker (light
0.5SEC,
extinguish
0.5SEC)
water full of water
tank
Normal, discharge the water out, it will return to normal condition
automatically
五、inverter single split series
LED
running
lamp(flicke
r times)
timer
lamp(flicke
r times)
failure
The reason of fault and solution
F1 1 light communication fault
1Check whether the connection of the outdoor unit and
indoor unit is one to one, otherwise connect the L, N
and communication line of the indoor unit and outdoor
unit one to one.
2Measure whether the voltage between the zero line and
the communication line is 18V-30AC half-wave signal,
check whether the communication circuit on the indoor
and outdoor electric control board has been damaged,
otherwise replace it.
3Check whether the LED on the outdoor power board has
been on, otherwise replace the electric control board.
4Check whether the unit is abnormal caused by the
external interference, if it is, then find the interfering
source, and removes it.
F2 2 light
ambient temp.
sensor fault
1 Check whether the resistance of sensor is normal,
otherwise replace it.
2Check whether the sensor wire is short circuit or open
circuit, and whether the plug is well contacted, whether
there is welding off or rosin joint on the electric control
board, repair it if there is any above.
3When the 1 and 2 are both normal, then the components
or integrated circuit is damaged, the electric control
board should be replaced.
F3 3 light
coil pipe temp.
sensor of indoor
unit
fault(inlet,middle
,outlet)
1Check whether the resistance of sensor is normal,
otherwise replace it.
2Check whether the sensor wire is short circuit or open
circuit, and whether the plug is well contacted, whether
there is welding off or rosin joint on the electric control
board, repair it if there is any above.
3When the 1 and 2 are both normal, then the components
or integrated circuit is damaged, the electric control
board should be replaced.
F4 4 light fan motor of indoor
1Check whether the contact of the plug of the motor wire