board, repair it if there is any above.
3、When the 1 and 2 are both normal, then the components
or integrated circuit is damaged, the electric control
board should be replaced.
FA 10 light
inductor of current
or voltage fault
1、Check whether inductor of current or voltage have been
damaged, they should be replaced if they are fault.
FC 11 light
compressor drive
fault
1、Power on again, and check the operation of the
compressor is normal.
2、Check whether the connection of the compressor is
reliable, otherwise repair.
3、Check whether the components on the electric control
board have been damaged, if they are damaged, the
components or the electric control board should be
replaced.
FD 12 light
phase lacking or
phase sequence
fault
1、Check power wire voltage or change two power wires.
FE 13 light
gas return sensor
fault(include
A,B,C,D)
1、Check whether the resistance of sensor is normal,
otherwise replace it.
2、Check whether the sensor wire is short circuit or open
circuit, and whether the plug is well contacted, whether
there is welding off or rosin joint on the electric control
board, repair it if there is any above.
3、When the 1 and 2 are both normal, then the components
or integrated circuit is damaged, the electric control
board should be replaced.
FF 14 light other fault
P1 1 light
temp. of evaporator
protection
1、Check whether the filter of indoor unit is too dirty, and it
should be cleaned when it is too dirty.
2、Check whether it has barrier around indoor unit,
it should be remove if it has.
3、Check whether the indoor motor is damaged, it should be
replaced motor or electrical control board when it is
damaged.
P2 2 light
overheat, over
current protection
of inverter module
1、 Check whether the fixation between the IPM module
and the radiator is firm.
2、Check whether the compressor is well, otherwise replace
it.
3、Check whether the IPM module is abnormal, otherwise
replace it.
P3 3 light
over current
protection
1、Check whether the ambient temperature exceeds the
operation range for the air conditioner
2、Check whether the current detection circuit is abnormal,
the electric control should be replaced when it is
abnormal.
P4 4 light
discharge temp. of
compressor
1、Check whether the air condition system and pressure are
normal.
Содержание
Похожие устройства
- Chigo CS/CU-25H3A-V84 Каталог Chigo 2011
- Chigo CS/CU-61H3A-P84 Инструкция по эксплуатации
- Chigo CS/CU-61H3A-P84 Сертификат
- Chigo CS/CU-61H3A-P84 Коды ошибок
- Chigo CS/CU-61H3A-P84 Каталог Chigo 2011
- Chigo CS/CU-21H3A-V84 Инструкция по эксплуатации
- Chigo CS/CU-21H3A-V84 Сертификат
- Chigo CS/CU-21H3A-V84 Коды ошибок
- Chigo CS/CU-21H3A-V84 Каталог Chigo 2011
- Rix I/O-W12S Инструкция по эксплуатации
- Rix I/O-W12S Инструкция по монтажу
- Rix I/O-W18S Инструкция по эксплуатации
- Chigo CS/CU-51H3A-P84 Инструкция по эксплуатации
- Chigo CS/CU-51H3A-P84 Сертификат
- Chigo CS/CU-51H3A-P84 Коды ошибок
- Chigo CS/CU-51H3A-P84 Каталог Chigo 2011
- Rix I/O-W09S Инструкция по эксплуатации
- Rix I/O-W09S Инструкция по монтажу
- Chigo CS/CU-32H3A-V84 Инструкция по эксплуатации
- Chigo CS/CU-32H3A-V84 Сертификат
Скачать
Случайные обсуждения