Sagi KUA2M (внутренний агрегат) [30/130] 12 c 24 c 12 c 24 c

Sagi KUB2A (внутренний агрегат) [30/130] 12 c 24 c 12 c 24 c
12
The “ ” led flashing indicates a delay in the activation of
the defrosting.
E0” flashing on the display can indicate one of the following
anomalies: improper type of cold room drill,
cold room drill or links defects, temperature out of the
temperature limit.
"E2" flashing on the display: corruption of the configuration
data in the memory; try to turn off the appliance and start it
again, if the alarm message disappears, change the heat
regulator.
Chamber temperature: if the display shows a correct value,
but the value is flashing, the temperature scanned by the
probe is behind the prefixed limits.
ALARMS AND SIGNALS (ELIWELL)
The alarm condition is always signalled by the buzzer (if
present) and by the led of the alarm icon .
To silence alarms press any key.
LED ON when the compressor is started up; blinking
in case of delay, protection or blocked enabling
LED ON when defrosting; blinking in case of manual
enabling
LED
ON when the alarm is enabled; blinking when
the alarm is silenced
The alarm signal produced by a faulty thermostat probe
(referred to probe 1) is shown as E1 on the instrument
display
The signals for maximum and minimum alarms do not
appear on the instrument display but are viewable on the
“Machine Status” menu in the “AL” folder.
AH1 = High temperature alarm (referred to the thermostat
probe or probe 1
AL1 = Low temperature alarm (referred to the thermostat
probe or probe 1)
COUNTERS: -2°C/+8°C
-12°C/-24°C
CONTROL PANELS
All products in the range use control panels with the following controls:
ON/SBY/ENTER key
Press and release this key to check/change the appliance operation setpoint.
Press this key for 3 seconds and release it as the display shows the [Sby] to set the appliance to
the stand-by mode.
Hold this key pressed for over 5 seconds (thus avoiding the Sby label) to gain access to the user
parameters list.
When holding device in stand-by pressed [the display shows Sby], the controller turns on.
UP and DOWN keys
These keys allow to increase or decrease the value of the parameter to be changed.
Hold these keys pressed for 3 seconds to get the min. and max. temperature recorded (if
available) and any activated alarms.
With the keyboard locked, press these keys simultaneously to unlock.
Press UP for 3 seconds to activate the Hyper Cold function.
Press DOWN for 3 seconds to de-activate the Hyper Cold function.
MENU key
Press this key for 3 seconds to activate/de-activate the appliance smart function input.
DEFROST ICON
Led on: defrost in progress
Led blinking: defrost activation delay or dripping in progress
Led blinking at high frequency: alarm memorized
POS
DESCRIPTION
1
ON/SBY/ENTER key
2
DOWN key
3
UP key
4
MENU key
5
DEFROST ICON
6
FAN ICON
7
COMPRESSOR ICON

Содержание