of the pipes is the ensure of adequate heat transfer surface area and to improve the
circulation of water in the water space of the water jacket. During normal operation, the flue
gases are “washing” the walls of the burning chamber and then a niche and external surfaces
of pipes, and then into the flue and chimney. Back to the "cold" water to the fireplace water
system is realized by means of the lower ports (left or right) welded to the side walls of
water jacket. Discharge of heated water from the water jacket is made left or right
(otherwise than return) top discharge port. The second connector is used to connect pipes of
safety.
4. Assembly and installation of a fireplace insert and cast iron stove
Before connecting the fireplace insert or stove read this manual and check the completeness
of its equipment. To ensure safe and economical operation of the fireplace is in good
working order and properly adjusted in terms of the diameter as well as a good seal duct,
made according to the building rules. Before connecting the fireplace insert to the chimney,
it is necessary to receive the flue by a qualified chimney sweep. The chimney at the bottom,
below the level of connection of the oven should be equipped with non-combustible, double
access door.
NOTE: Each fireplace insert must be connected to a separate flue pipe of the appropriate
chimney draft (10-15 Pa).
Chimneys should be located in the walls between the heated rooms. When the chimney is
located in the wall of the building, perform the isolation of a material resistant to high
temperatures. Its absence may result in lowering the temperature of the exhaust gases and
loss the flue draft. Diameter of the flue should not be less than the diameter of duct into the
chimney. If the flue outlet exhaust gas damper is installed, it is in the closed position it
should have a section which is not obscured by at least 25% of the diameter of the exhaust
duct. Chimneys should be installed above the roof in accordance with the applicable
standard. Smoke pipe outlets should be done according to the following rules:
flat roofs with a slope of roof slopes of less than 12 °, regardless of the roof structure,
vents should be located at least 0.6 m above the level of the ridge or edge of the
building with sunken roofs.
the steep roofs with a slope roofs over 12 ° and coverage:
o the easily inflamed, flue outlets should be at least 0.6 meters above the level of the
ridge,
o a non-combustible, non-inflammatory and inflammatory difficult, outlet pipe should
be at least 0.3 m from the surface of the roof and in the distance measured in the
horizontal direction of the surface of at least 1.0 m.
The location of the chimney of the building next to the item causing an obstruction for
the proper functioning of chimney, the outlet should be in addition:
o over the plane of derived for 12 ° down to the level of the highest obstacles for
chimneys located at a distance of 3 to 10 meters from the obstacle with steep roofs,