KAW-МЕТ P10 [18/52] Recommendations for housing and installation of furnace

KAW-МЕТ P10 [18/52] Recommendations for housing and installation of furnace
18
o at least at the upper edge of the obstacles for chimneys located at a distance of 1.5
to 3.0 m from the obstacle,
o of at least 0.3 m above the top of the obstacles for chimneys located at a distance of
1.5 m from the obstacle.
Installation and commissioning of the fireplace/stove should be done by a qualified assembly
team.
Before setting the fireplace insert with water jacket make a foundation for a minimum of
5 cm above the floor of the room where the fireplace is to be used. Set on the foundation of
a fireplace should be level and then make the connections for central heating and flue. Then
proceed with the installation of accessories. Flue outlet must be connected to the chimney
using a steel pipe, which must be mounted on the flue and put in the chimney. Filling of
water in the heating system should be made not less than 1 m from fire place insert on the
return water pipe. Installation and commissioning of fireplace insert should be performed by
a qualified installation team.
We are not responsible for the installations comply with standards or recommendations
contained herein or for systems in which they are used more inappropriate materials.
5. Recommendations for housing and installation of furnace
The prefabricated elements should be combined with modelling glue and sisal.
Pillars of the side bar and fireplace hood should be related to the wall, which is based on
a fireplace.
Housing should be made of non-combustible materials.
If the beam is made of wood, should be protected by ring of concrete and mineral wool
insulation with aluminium foil. There should be adequate space between the furnace and
the protective elements beam. Beams stone must necessarily be attached to the wall.
To make a hood is recommended to use heat-resistant panels reinforced with glass fibber
with a minimum thickness 20 mm. The interior of the hood should be put mineral wool with
aluminium coating inward the fireplace. Within minimum 30 cm from the ceiling make
horizontal deflector that directs the heat generated by the furnace into grilles mounted
below the deflector. Ventilation should have a surface min. 400 cm ² and be at least 30 cm
from the ceiling. The interior of the housing in the lower part to bring air from the room to
keep the heat exchange such as the niche in the wood in the fireplace or by installing a
ventilation grille in the lower parts of the side pillars. Ensuring the exchange of air in the
furnace housing is mandatory. The enclosure should be as large as possible so as not to
accumulate too much heat in the hood.
Fresh air intake
If the air supply is insufficient to housing such as apartments equipped with mechanical
ventilation must take additional fresh air supply to the fire from the outside or in the
basement, if it is not heated in the winter. Diameter of air intake should be at least ¼ of the