2. TECHNICAL DATA
Denition in according to:
Constructive system
Nominal thermal power in kW
Efciency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Depression by rating caloric value in Pa (mm H
2
O) - wood
Hourly wood consumption in Kg/h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s - wood
Exhaust gas temperature in °C - wood
Outer air inlet Ø in mm (minimum surface cm
2
)
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill Movable - at
Height in mm
Width in mm
Depth in mm
Weight in Kg
Fire prevention safety distances Chapter FIRE SAFETY
m
3
riscaldabili (30 kcal/h x m
3
) (#)
(#) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of
the stoves is:favourable type of building (30 Kcal/h x m
3
); less favourable type of building (40 Kcal/h x m
3
); unfavourable type of building
(50 Kcal/h x m
3
).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reducWed by about 25%.
3. GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualied technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole. La NORDICA S.p.A. declines any responsibility for the product that has been modied without written
authorisation as well as for the use of non-original spare parts.
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also reproof
rules.
NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A. cannot be held responsible for lack of
respect for such precautions.
4. INSTALLATION REGULATIONS
Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for nal installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing ue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
UPPER smoke output - REAR - LATERAL
verify if your structure can support the weight of the appliance. In case of insufcient carrying capacity it is necessary to
adopt appropriate measures, La NORDICA responsibility is limited to the supply of the appliance (See chapter TECHNICAL
DESCRIPTION).
Make sure that the oor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of ammable
CUCINOTTA
EN 12815
1
9,1
78
150
4 - 200x200 Ø200
12 ( 1,2 mm H
2
O)
2,8
0,11 - 1375 mg/m
3
9,5
310
150 (100 cm
2
)
405 x 325
423 x 346 x 475
-
860
682
653
197
261