MCZ Anthea [11/27] Chimenypot
![MCZ Anthea [11/27] Chimenypot](/views2/1336264/page11/bgb.png)
INSTALLATION AND USE MANUAL
Chapter 2
page
11
Theoretic notions for installation
Technical service - MCZ S.p.A. all rights reserved - Reproduction prohibited
2.6. CHIMENYPOT
If underestimated, it is a terminal impediment to correct "chimney
system" operations.
Chimney flue draught is also a function of its chimneypot.
Therefore, if hand made, its four exhaust sections must correspond to
the more than twice the internal section of the chimney flue.
Having to exceed the peak of the roof, the chimneypot will be
exposed to wind, therefore an industrial type is recommended.
Industrial
chimneypot with
overlapping
prefabricated
elements.
Permits excellent
smoke exhaust.
Traditional hand
made chimneypot.
The right exhaust
section must be at
least twice the
internal section of
the chimney flue,
2.5 times is ideal.
Steel chimneypot for
chimney flue with
internal smoke
deflector cone.
Permits excellent
smoke exhaust.
Chimneypots must meet the following requisites:
• They must have an internal section equal to that of the
chimney.
• They must have a useful output section not less that double
that of the internal section of the chimney flue.
• They must be built to prevent rain, snow and any foreign
object penetration in the chimney flue.
• They most be installed to guarantee excellent smoke
dispersion and out of the reflux are where counter-pressure
formation is favoured.
For paired chimney flues, the chimneypot for solid
combustion and the one for the upper floor must be at
least 50cm higher than the other to avoid pressure
transfers between paired flues.
The chimneypot must not have obstacles within 10 mt
such as walls, waterbeds and trees. Otherwise, raise it
at least 1 mt over the obstacle and, in the event of
other nearby chimneypots, keep them at least 2 mt
away and, in any case, the chimneypot must exceed
the peak of the roof by at least 1mt.
UPPER FLOOR OR
SOLID COMBUSTION
LOWER FLOOR
1
m
t
0
,
5
m
t
YES
NO
Содержание
- Anthea myria luna quasar nadir pulsar sirio zenit venus cometa alpha orion modulo legna 1
- Bimschv art 15a b vg vkf aeai regensburger bstv erfüllt 2
- Bimschv art 15a b vg vkf aeai regensburger münchener bstv erfüllt 2
- Contents technical service mcz s p a all rights reserved reproduction prohibited 2
- Leggere e seguire le istruzioni lire et suivre les instructions bedienungsanleitung lesen und beachten lees en respecteer de aanwijzingen 2
- Mg nm3 13 o2 33 mg mj 2
- Mg nm3 13 o2 9 mg mj 2
- Modulo legna 2
- Quasar 2
- How to read the manual 4
- Introduction 4
- Manual preservation 4
- Revisions to the publication 4
- Script 4
- Operating warnings 5
- Safety warnings 5
- Warnings and warranty conditions 5
- Warranty conditions 5
- Exclusions 6
- Restrictions 6
- Notions for installation according to uni 10683 7
- Operating area 7
- Precautions 7
- External air outlet 8
- Chimney flue 9
- Chimney flue connections 9
- Max 2 mt 9
- Examples of chimney flues 10
- Chimenypot 11
- Dimensions and technical specifications 12
- Prestige line 12
- Ø 150 12
- 320 ø 150 13
- Ø 150 13
- 320 ø 150 14
- Design line 15
- Ø 150 15
- Ø 150 17
- Modulo line 18
- Ø 150 18
- Installation and assembly 19
- Positioning 19
- Preparation and unpacking 19
- Assembly and feet adjustment 20
- Ceramics assembly 20
- Frame assembly wood module 20
- Do not demand full heating performance straight away 21
- Operation 21
- Pre lighting warnings 21
- Control of combustion 22
- Loading the fuel 22
- Stove use 22
- First lighting 23
- Max min 23
- Model adjustments luna myria anthea modulo 23
- Model adjustments pulsar nadir 23
- Model adjustments quasar orion sirio venus cometa zenit alpha 23
- Attention 24
- Chapter 24
- Emergency treatment 25
- Cleaning of stainless steel and satin finish surfaces 26
- Cleaning out the ashes 26
- Cleaning the glass 26
- Cleaning to be performed by the user 26
- Cleaning upper calorite deflectors 26
- Maintenance and cleaning 26
- Cleaning and characteristics of marble and steatite cladding 27
- Cleaning by specialised personnel 27
- Cleaning flue pipe 27
- Cleaning of painted parts 27
Похожие устройства
- Starfood BQ 318 N Инструкция по эксплуатации
- Besser Vacuum Breeze Инструкция по эксплуатации
- Besser Vacuum Calima Инструкция по эксплуатации
- Besser Vacuum Fresh 43 Инструкция по эксплуатации
- Casadio Undici S2 Инструкция по эксплуатации
- Вулкан BPF 01 «Хоному» Инструкция по эксплуатации
- ТММ СХСБ-1/8Я (2280x700x870) (внутренний агрегат) Инструкция по эксплуатации
- ATESY Диксон СТХ-3/1670М с ящиками (внутренний агрегат) Инструкция по эксплуатации
- ATESY Диксон СТХ-3/1670М с ящиками (внутренний агрегат) Декларация о соответствии
- UNOX XEBC-06EU-EPR-SP Инструкция по установке
- UNOX XEBC-06EU-EPR-SP Каталог оборудования UNOX серии BakerTop MIND.Maps
- UNOX XEBC-10EU-EPR-SP Инструкция по установке
- UNOX XEBC-10EU-EPR-SP Каталог оборудования UNOX серии BakerTop MIND.Maps
- UNOX XEVC-0711-EPR-SP Инструкция по установке
- UNOX XEVC-0711-EPR-SP Каталог оборудования UNOX серии ChefTop MIND.Maps
- UNOX XEVC-1011-EPR-SP Инструкция по установке
- UNOX XEVC-1011-EPR-SP Каталог оборудования UNOX серии ChefTop MIND.Maps
- ROAL SB-6000 Инструкция по эксплуатации
- UNOX XEVC-0511-EPR-SP Инструкция по установке
- UNOX XEVC-0511-EPR-SP Каталог оборудования UNOX серии ChefTop MIND.Maps