Faber T-LIGHT EV8P WH MATT A90 (110.0456.269) [5/100] Controls

Faber T-LIGHT EV8P WH MATT A90 (110.0456.269) [5/100] Controls
5
Z
Clean the hood using a damp
cloth and a neutral liquid de-
tergent.
Controls
ABCDE
Button Function Led
A Turns the motor on/off at speed one. Fixed.
With the motor turned off:
6DWXUDWLRQ RI WKH JUHDVH ¿OWHUV WDNHV SODFH DIWHU  KRXUV RI FRQWLQXRXV
operation of the hood.
Flashes once a
second.
With the motor turned off:
6DWXUDWLRQ RI WKH DFWLYDWHG FKDUFRDO ¿OWHUV WDNHV SODFH DIWHU  KRXUV RI
continuous operation of the hood.
Flashes once
every 0.5
seconds.
B Turns the motor on at speed two. On.
Press and hold the button for approximately 2 seconds, with all the loads turned
off (Motor+Lights), to turn the Activated Charcoal Filter alarm on. LED (A) ÀDVKHV
WZLFH WRFRQ¿UP
To turn the alarm off, press the button again and hold for at least 2 seconds. The
UHOHYDQW /('ÀDVKHV RQFH (A).
Flashing.
C Turns the Motor on at speed three. On.
Press and hold the button for approximately 2 seconds, with all the loads turned
off (Motor+Lights), to reset the Filter saturation alarm. LED AÀDVKHVWKUHHWLPHV
Flashing.
D Turns the motor on at INTENSIVE speed.
This speed is timed to run for 6 minutes. At the end of this time, the system returns
automatically to the speed that was set before. If it is activated with the motor turned
off, it will switch to OFF at the end of the time. To deactivate it, press button D
once more or press button A.
Flashing.
With all the loads turned off (Motor+Lights), press and hold D for approximately
2 seconds to enable the remote control. Button AÀDVKHV WZLFH
With all the loads turned off (Motor+Lights), press and hold D for approximately
2 seconds to disable the remote control. Button AÀDVKHV RQFH
Flashing.
E PANEL CLOSED
Turns the lights on/off at maximum strength.
On.
PANEL OPEN
Light off.
-
Lighting
For replacement contact tech-
nical support (“To purchase
contact technical support”).