Lincat J10pFL [12/17] J5 j10 component replacement
![Lincat J5nFL [12/17] J5 j10 component replacement](/views2/1337693/page12/bgc.png)
12
J5/J10 Component Replacement.
Ignitor Electrode and Pilot Jet
1. Undo pilot gas feed pipe, the pilot jet will come away when the pipe is removed.
2. Undo two screws attaching pilot mounting bracket to front of burner chassis and drop pilot assembly
clear of chassis.
3. Disconnect igniter lead from bottom of igniter.
4. Remove igniter electrode, held to bracket by a single screw.
5. Reversal of above for reassembly. Ensure pilot jet is refitted when fitting pilot pipe.
Thermocouple. (This operation is easier if the pilot assembly is removed, see above).
1. Undo the brass nut on top of the bracket which secures the thermocouple to the pilot bracket and pull
down.
2. Undo the nut holding the thermocouple into the rear of the valve.
3. Disconnect the wires from the interrupter terminal block
4. Replace the thermocouple
5. Reversal of the above for re assembly.
Thermopile.
1. Disconnect the thermopile lead at the control valve.
2. Loosen the thermopile retaining nut located underneath the pilot assembly.
3. Withdraw the thermopile from the pilot bracket.
4. Reversal of above for reassembly.
Control Thermostat.
1. Drain fryer
2. Remove the Thermostat control knob and the control panel facia.
3. Disconnect the wires from the thermostat and remove the screws holding the thermostat to the facia.
4. Remove the small gland assembly nut where the capillary enters the tank.
5. Free the thermostat phial from thermostat clip inside tank.
6. Reversal of the above for re assembly.
Содержание
- Silverlink 600 gas fryer j5 and j10 1
- User and installation instructions 1
- Foreword 3 2
- Installation instructions 4 6 2
- Notes on frying 7 8 2
- Operating instructions 9 10 2
- Service 17 2
- Servicing 11 13 2
- Spares list 16 2
- Technical specification 16 2
- Troubleshooting 14 15 2
- Consequential loss 3
- Foreword 3
- Important 3
- Maintenance 3
- Warning 3
- Before commencing installation of the appliance please take time to read the following installation instructions carefully parts protected by the manufacturer are not to be adjusted by the installer or user 4
- Stabilising kit installation instructions 5
- After setting ensure the governor cap is properly secured and the blanking screws replaced in 6
- Anticlockwise to reduce it 6
- Fig 1 c 6
- Inlet pressure refer to technical data table on page 16 6
- Method described above to the value shown on the technical data table page 16 6
- Remove the governor cap and turn the screw clockwise to increase the outlet pressure and 6
- The test points 6
- Use the test point marked out fig 1 b to set the unit to the appropriate burner pressure 3 adjustment is made via the valve s onboard governor which is situated centrally on the valve 6
- Use the test point provided on the gas control valve marked in fig 1 a to check the supply 6
- With main burner lit refer to operating instructions page 9 adjust the burner pressure by the 6
- C before draining 7
- Notes on frying media 7
- Warning always allow oil to cool to a maximum 55 7
- A guide to frying times 8
- Frozen foods 8
- Frying tips 8
- Oil capacity 8
- A a thermostat knob b control valve c pilot d limit reset location e drain valve blanking cap f drain valve lock g drain valve handle 9
- Lighting of the appliance please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit 9
- Note lids must not be used when cooking is in progres 9
- Operating instructions 9
- Cleaning instructions 10
- Drainage 10
- Preparation for use 10
- Shut down of the appliance 10
- Standby 10
- J5 j10 general service 11
- Servicing 11
- Control thermostat 12
- Disconnect the thermopile lead at the control valve 12
- Ignitor electrode and pilot jet 12
- J5 j10 component replacement 12
- Loosen the thermopile retaining nut located underneath the pilot assembly 12
- Reversal of above for reassembly 12
- Thermocouple this operation is easier if the pilot assembly is removed see above 12
- Thermopile 12
- Withdraw the thermopile from the pilot bracket 12
- Burner 13
- The burner can now be removed through the rear access opening 13
- Fault finding 14
- Models j5 and j1 16
- Natural gas g20 16
- Propane gas g31 16
- Spares list the following components are listed with the lincat reference number followed by a brief description ig14 ignitor electrode ig19 piezo igniter pi25 pilot assembly tc19 thermocouple tc20 thermopile th99 control thermostat th96 safety limit thermostat va20 gas control valve 16
- Technical data 16
- 01522 500881 17
- Authorised service agents 17
- Conditions of guarantee 17
- Gas catering equipment should be routinely serviced to ensure a long trouble free life with this in 17
- Lincat service help desk 17
- Mind it is recommended that the appliances are serviced every 6 months by a competent gas engineer 17
- Service 17
Похожие устройства
- Lincat J10pFL Каталог оборудования Lincat (англ.)
- Lincat J10nFL Инструкция по эксплуатации
- Lincat J10nFL Каталог оборудования Lincat (англ.)
- Lincat J5nFL Инструкция по эксплуатации
- Lincat J5nFL Каталог оборудования Lincat (англ.)
- Lincat LBM2W Инструкция по эксплуатации
- Lincat LBM2W Каталог оборудования Lincat (англ.)
- Robot Coupe CL55 рабочая станция Инструкция по эксплуатации
- Robot Coupe CL55 рабочая станция Каталог оборудования Robot Coupe
- Lincat LBR2 Инструкция по эксплуатации
- Lincat LBR2 Каталог оборудования Lincat (англ.)
- Vatten FI104XTKGMO BUILT-IN Инструкция по эксплуатации
- Vatten FI104XTKGMO BUILT-IN Сертификат
- Lincat LCG2 Инструкция по эксплуатации
- Lincat LCG2 Каталог оборудования Lincat (англ.)
- Lincat LGR2 Инструкция по эксплуатации
- Lincat LGR2 Каталог оборудования Lincat (англ.)
- Lincat LD4 Инструкция по эксплуатации
- Lincat LD4 Каталог оборудования Lincat (англ.)
- Lincat LRG2 Инструкция по эксплуатации