FOREWORD
Thank you for buying this Lincat product, which we hope will give you years of trouble free service.
To ensure you receive the maximum benefit from your new fryer please take the time to read this
instruction book carefully, following any directions given.
We manufacture over 300 different items of catering equipment and are constantly adding to and
improving the range.
If you‟re thinking of extending your kitchen or renewing a catering appliance in the near future, see
our sales brochures available from your local distributor or send for one direct from us before you
make your decision.
IMPORTANT
Please read this page carefully before initially using the equipment.
WARNING
This appliance must be installed and serviced by a registered engineer.
Whilst in operation, parts of the catering equipment will become hot. Suitable precautions must be taken to
avoid accidental burns, therefore the appliance should be positioned to minimise the possibility of accidental
touching.
This appliance is for professional use and shall be operated by qualified personnel.
CONSEQUENTIAL LOSS
Lincat do not accept any responsibility for loss of food, production time, profit, etc., which may result from
a break-down of the equipment
MAINTENANCE
1) These units must not be cleaned using a water jet.
2) Clean units with water and detergent - do not use abrasives.
Содержание
- User and installation instructions p.1
- Silverlink 600 gas fryer j5 and j10 p.1
- Installation instructions 4 6 p.2
- Foreword 3 p.2
- Troubleshooting 14 15 p.2
- Technical specification 16 p.2
- Spares list 16 p.2
- Servicing 11 13 p.2
- Service 17 p.2
- Operating instructions 9 10 p.2
- Notes on frying 7 8 p.2
- Warning p.3
- Maintenance p.3
- Important p.3
- Foreword p.3
- Consequential loss p.3
- Before commencing installation of the appliance please take time to read the following installation instructions carefully parts protected by the manufacturer are not to be adjusted by the installer or user p.4
- Stabilising kit installation instructions p.5
- Anticlockwise to reduce it p.6
- After setting ensure the governor cap is properly secured and the blanking screws replaced in p.6
- With main burner lit refer to operating instructions page 9 adjust the burner pressure by the p.6
- Use the test point provided on the gas control valve marked in fig 1 a to check the supply p.6
- Use the test point marked out fig 1 b to set the unit to the appropriate burner pressure 3 adjustment is made via the valve s onboard governor which is situated centrally on the valve p.6
- The test points p.6
- Remove the governor cap and turn the screw clockwise to increase the outlet pressure and p.6
- Method described above to the value shown on the technical data table page 16 p.6
- Inlet pressure refer to technical data table on page 16 p.6
- Fig 1 c p.6
- Warning always allow oil to cool to a maximum 55 p.7
- Notes on frying media p.7
- C before draining p.7
- Oil capacity p.8
- Frying tips p.8
- Frozen foods p.8
- A guide to frying times p.8
- A a thermostat knob b control valve c pilot d limit reset location e drain valve blanking cap f drain valve lock g drain valve handle p.9
- Operating instructions p.9
- Note lids must not be used when cooking is in progres p.9
- Lighting of the appliance please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit p.9
- Standby p.10
- Shut down of the appliance p.10
- Preparation for use p.10
- Drainage p.10
- Cleaning instructions p.10
- Servicing p.11
- J5 j10 general service p.11
- Reversal of above for reassembly p.12
- Loosen the thermopile retaining nut located underneath the pilot assembly p.12
- J5 j10 component replacement p.12
- Ignitor electrode and pilot jet p.12
- Disconnect the thermopile lead at the control valve p.12
- Control thermostat p.12
- Withdraw the thermopile from the pilot bracket p.12
- Thermopile p.12
- Thermocouple this operation is easier if the pilot assembly is removed see above p.12
- The burner can now be removed through the rear access opening p.13
- Burner p.13
- Fault finding p.14
- Technical data p.16
- Spares list the following components are listed with the lincat reference number followed by a brief description ig14 ignitor electrode ig19 piezo igniter pi25 pilot assembly tc19 thermocouple tc20 thermopile th99 control thermostat th96 safety limit thermostat va20 gas control valve p.16
- Propane gas g31 p.16
- Natural gas g20 p.16
- Models j5 and j1 p.16
- Lincat service help desk p.17
- Gas catering equipment should be routinely serviced to ensure a long trouble free life with this in p.17
- Conditions of guarantee p.17
- Authorised service agents p.17
- 01522 500881 p.17
- Service p.17
- Mind it is recommended that the appliances are serviced every 6 months by a competent gas engineer p.17
Похожие устройства
-
Lincat J5nFLКаталог оборудования Lincat (англ.) -
Lincat J5nFLИнструкция по эксплуатации -
Lincat J10nFLКаталог оборудования Lincat (англ.) -
Lincat J10nFLИнструкция по эксплуатации -
Lincat J10pFLКаталог оборудования Lincat (англ.) -
Lincat DF7pFLКаталог оборудования Lincat (англ.) -
Lincat DF7pFLИнструкция по эксплуатации -
Lincat DF618FLКаталог оборудования Lincat (англ.) -
Lincat DF618FLИнструкция по эксплуатации -
Lincat DF39FLКаталог оборудования Lincat (англ.) -
Lincat DF39FLИнструкция по эксплуатации -
Lincat DF4pFLКаталог оборудования Lincat (англ.)
Изучите важные рекомендации по использованию и обслуживанию профессионального кухонного оборудования для обеспечения его долгосрочной работы и безопасности.