SAFETY PRECAUTIONS Please read and observe
by all means!
WARNING:
Dangerous ultraviolet radiation!
Never look directly into the UV-C lamp without pro-
tection when it is operating (eye damage!).
The sera UV-C lamp may be operated only in com-
pletely assembled condition (please refer to directions
for use for information about readiness to use). Every
other use may lead to very severe skin and eye dam-
age!
The casing of the lamp must not be opened or dam-
aged.
Always keep UV units and UV-C lamps out of the reach
of children!
The unit must not be operated at temperatures above
35°C (95°F) or in case of frost.
Never operate the UV-C system and the pump with-
out water ow!
Too frequent “ON/OFF” switching reduces the life ex-
pectancy of the UV-C lamp. The unit should be oper-
ated permanently for 24 h/d as to achieve best pos-
sible results.
All electrical units located in the water must be dis
-
connected from the mains/power supply before con-
ducting work at the aquarium.
Make sure that the voltage of the mains supply com-
plies with the data on the type plate.
Bend the mains cord into a drip loop as to prevent wa-
ter running along the cable into the socket.
Operate all units only with an inserted fault current
protection switch (RCD or FI with a trip current of
30 mA).
Ensure plug and outlet is accessible to reach at all
times.
The transformer and the ballast must be protected
against water.
The unit must not be operated in case the electrical
cords are damaged.
The  and its
components may only be used for the described oper-
ational purpose.
Thank you for choosing the new sera bioactive IF 400
+ UV .
This novel internal lter combines the advantages of a
lter with large lter volume for the powerful bio ltration
located inside the aquarium with a simultaneous UV-C
treatment of the ltered aquarium water. UV-C is hard
radiation that has a partially sterilizing effect on the
aquarium water and reduces pathogenic pressure in
the aquarium. Parasites and their larvae are also removed
from the aquarium water entirely without using chemi-
cals.
The  has an in-
ternal modular design and includes 6 lter baskets (5.1)
that can be equipped individually. Also, it can be individ-
ually adjusted to the desired function (fast ow lter, spe-
cial lter, 5.3, 5.4) with a few turns. The performance
of the included  can be
adjusted to maximum 750 l/h (198 US gph). The sera UV-C
System 5 W, which does not require an other pump, is
connected to it. The sera bioactive IF 400 + UV internal
 is energy saving and quiet. The ltered water leaves
the lter through a exible current distributor. The currents
in the aquarium benet of this feature. The lter is both
suitable for freshwater as well as marine aquariums.
Kit includes (1)
1.1 Filter casing with slot shaped intake openings
1.2 Cover
1.3 Holder rail
1.4 Filter media basket with lateral lid (1.5) for lling
1.6 Central holder plates
1.7 
1.8 Connection hose
1.9 sera UV-C System 5 W (consisting of transform-
er, ballast and UV-C lamp 5 W)
1.10 Connection piece (outlet)
1.11 sera current distributor with two movable current
nozzles
sera siporax mini Professional lter medium
Assembly and operation
The lter is attached to the aquarium glass with a hold-
er rail (see g. 1.3) glued on with common aquarium sil-
icone. Due to this kind of attaching, it will cling to the
aquarium glass not only permanently, but also so close
to the aquarium glass that no sh can swim between the
lter and the aquarium glass.
Installation with new setups
1. Put the lter into the empty, dry aquarium and place
the hood on the tank. Check how high the sera bio-
active IF 400 + UV  including lid can be
installed without touching the hood. The upper edge
of the lter should be approximately 1 2 cm (0.4
0.8 in.) below the upper edge of the tank (2.1). Mark
the installation area of the holder rail on the outside of
the aquarium with an overhead marker or a grease
pencil.
2. Place the aquarium vertically on the side pane on
which the lter is to be attached. Make sure the un-
derground is even, smooth and clean possibly place
a blanket or a Styrofoam slab underneath.

Information for use


this information for use is also to be handed over.
sera bioactive IF 400 + UV Innenfilter neu.indd 12 21.08.2014 15:43:47