6.6 Cable sizing
Grundfos can supply submersible drop cables for
any type of installation.
The table values below are calculated from the
following formula:
where
q = Cross-section of submersible drop cable
[mm
2
].
I = Rated maximum current of the motor [A].
PF = 1.0.
L = Length of submersible drop cable [m].
ρ = Specific resistance: 0.02 [Ωmm
2
/m].
U = Nominal voltage [V].
ΔU = Voltage drop [%] = 4 %.
The 4 % voltage drop is according to IEC 3-64,
HD-384 Series.
The calculation gives the following maximum cable
lengths at a supply voltage of 240 V:
Caution
The cross-section of the submersible drop
cable must be large enough to meet the
voltage requirements specified in section
5.1 General.
q=
I x 2 x 100 x PF x L x ρ
U x ΔU
Max. cable length [m]
Motor
(P2)
I
N
Cable size
1.5 mm
2
2.1 mm
2
/
14 AWG
2.5 mm
2
3.3 mm
2
/
12 AWG
4 mm
2
6 mm
2
[kW] [A]
0.7 5.2 80 112 133 176 213 320
1.15 8.4 50 69 83 109 132 198
1.55 11.0 37 52 62 82 99 149
1.85 12 35 49 58 76 92 139