6.2. How to read the measurement value of the built-in temperature sensors.
MultiSync C431/ C501/ C551 have three built-in temperature sensors.
The controller can monitor inside temperatures by using those sensors with external control.
The following shows the procedure for reading the temperatures from the sensors.
Step 1. Select a temperature sensor which you want to read.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'8' (37h, 38h): Operation code is 78h (on page 2).
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Select the temperature sensor #1 (01h).
00h: No meaning
01h: Sensor #1
02h: Sensor #2
03h: Sensor #3
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “ Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies for confirmation.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicates a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'8' (37h, 38h): Operation code is 78h (in the page 2).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of temperature sensors are 3 (0003h).
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is #1.
ETX (03h): End of Message
Header Message Check
code
Delimiter
SOH-'0'-Monitor ID-
'0'-'E'-'0'-'A'
STX-'0'-'2'-'7'-'8'-
'0'-'0'-'0'-'1'-ETX
BCC CR
Header Message Check
code
Delimiter
SOH-'0'-'0'-Monitor ID-
'F'-'1'-'2'
STX-'0'-'0'-'0'-'2'-'7'-'8'-'0'-'0'-
'0'-'0'-'0'-'3'-'0'-'0'-'0'-'1'-ETX
BCC CR
Содержание
129- Rev g5 index
- External control nec lcd monitor
- I application
- Lan control
- Ii preparation
- Connectors and wiring
- Rs 232c remote control
- Rs 232c remote control
- Lan control
- Iii communication specification
- Communication timing
- Communication parameter
- Set parameter
- Save current setting command reply
- Save current setting command
- Monitor controller
- Get parameter reply
- Get parameter
- Communication format
- Command reply
- Command
- Header block format fixed length
- Message block format
- Source address
- Soh reserved destination
- Op code set value etx
- Message length stx op code
- Message
- Header message check code bcc
- Delimiter
- Check code
- Address
- Message type
- Get current parameter from a monitor
- Get parameter reply
- Set parameter
- Set parameter reply
- Commands
- Save current settings
- Get timing report and timing reply
- Null message
- Typical procedure example
- Iv control commands
- How to change the backlight setting
- How to read the measurement value of the built in temperature sensors
- Picture
- Operation code op code table
- Brigtness
- Aspect
- Adjust
- Balance
- Advanced
- Equlizer
- Audio delay
- Schedule
- Schdule
- Terminal setting
- Multi input
- Custom detect
- Tile matrix
- Multi display
- Screen saver
- Power on delay
- Motion
- Ir lock setting
- Heat status
- Display protection
- Control
- Key lock setting
- Auto dimming
- System
- Room light sensing
- Power indicator
- Monitor information
- Backlight setting
- Power status read
- Power control procedure
- Power control
- Asset data read request and reply
- Asset data read and write
- Asset data write
- Date time read and write
- Date time read
- This command is used in order to write the setting of the date time
- The controller requests the monitor to write date time
- Date time write
- Schedule read and write
- Schedule read
- Schedule write
- Holiday read and write
- Holiday read
- This command is used in order to write the setting of holiday
- The controller requests the monitor to write date time
- Holiday write
- Weekend read and write
- Weekend read
- Weekend write
- This command is used in order to write the setting of weekend
- The controller requests the monitor to write the setting of weekend
- Self diagnosis status read
- Self diagnosis
- Serial no model name read
- Serial no read
- Model name read
- Security lock control
- Security lock
- Daylight saving read write
- Daylight saving read
- Daylight saving write
- Firmware version read
- Firmware version
- Input name read
- Input name
- Input name write
- Input name reset
- Power save mode read
- Power save mode
- Power save mode write
- Auto power save time read
- Auto power save time write
- Security enable read
- Security enable
- Security enable write
- Lan mac address read
- Lan mac address
- Emergency contents display
- Emergency contents
- Emergency contents delete
- All data are subject to change without notice
Похожие устройства
-
Nec MultiSync V323-3Инструкция по эксплуатации -
Nec MultiSync V323-3Спецификация -
Nec MultiSync UN552VSИнструкция по эксплуатации -
Nec MultiSync UN552VSСпецификация -
Nec MultiSync UN552SИнструкция по эксплуатации -
Nec MultiSync UN552SСпецификация -
Nec MultiSync UN552VИнструкция по эксплуатации -
Nec MultiSync UN552VСпецификация -
Nec MultiSync UN552Инструкция по эксплуатации -
Nec MultiSync UN552Спецификация -
Nec MultiSync V323-3 PGИнструкция по эксплуатации -
Nec MultiSync V323-3 PGСпецификация
Узнайте, как правильно считывать значения встроенных температурных датчиков. Подробная инструкция по выбору датчика и интерпретации данных.