Nec MultiSync C501 — чтение и запись данных активов: инструкция и протоколы [41/101]
Превью страниц
Страница 41 /
101
![Nec MultiSync C501 [41/101] Asset data read and write](/views2/1375369/page41/bg29.png)
(41/104)
8. Asset Data read and write
MultiSync C431/ C501/ C551 have the area for to store user’s asset data of up to 64bytes.
8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header Message Check
code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'A'
STX-'C'-'0'-'0'-'B'-
'0'-'0'-'2'-'0'-ETX
BCC CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'C'-'0'-'0'-'B' (43h, 30h, 30h, 42h): Asset read request command.
'0'-'0' (30h, 30h): Offset data from top of the Asset data.
At first set 00h: Read data from the top of Asset data area.
'2'-'0' (32h, 30h): Read out data length is 32bytes.
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area.
Maximum readout length is 32bytes at a time.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “ Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
Header Message Check
code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-N-N
STX-'C'-'1'-'0'-'B'-
Data(0)-Data(1)---Data(N)-ETX
BCC CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
N-N: Message length
Note.) This length includes STX and ETX.
Message
STX (02h): Start of Message
'C'-'1'-'0'-'B' (43h, 31h, 30h, 42h): Asset read reply command
Data(0) – Data(N): Retuned Asset data
Ex.) When Data(n) is 1234h, replying data is (31h 32h, 33h, 34h).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “ Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Содержание
129- Rev g5 index
- External control nec lcd monitor
- I application
- Lan control
- Ii preparation
- Connectors and wiring
- Rs 232c remote control
- Rs 232c remote control
- Lan control
- Iii communication specification
- Communication timing
- Communication parameter
- Set parameter
- Save current setting command reply
- Save current setting command
- Monitor controller
- Get parameter reply
- Get parameter
- Communication format
- Command reply
- Command
- Header block format fixed length
- Message block format
- Source address
- Soh reserved destination
- Op code set value etx
- Message length stx op code
- Message
- Header message check code bcc
- Delimiter
- Check code
- Address
- Message type
- Get current parameter from a monitor
- Get parameter reply
- Set parameter
- Set parameter reply
- Commands
- Save current settings
- Get timing report and timing reply
- Null message
- Typical procedure example
- Iv control commands
- How to change the backlight setting
- How to read the measurement value of the built in temperature sensors
- Picture
- Operation code op code table
- Brigtness
- Aspect
- Adjust
- Balance
- Advanced
- Equlizer
- Audio delay
- Schedule
- Schdule
- Terminal setting
- Multi input
- Custom detect
- Tile matrix
- Multi display
- Screen saver
- Power on delay
- Motion
- Ir lock setting
- Heat status
- Display protection
- Control
- Key lock setting
- Auto dimming
- System
- Room light sensing
- Power indicator
- Monitor information
- Backlight setting
- Power status read
- Power control procedure
- Power control
- Asset data read request and reply
- Asset data read and write
- Asset data write
- Date time read and write
- Date time read
- This command is used in order to write the setting of the date time
- The controller requests the monitor to write date time
- Date time write
- Schedule read and write
- Schedule read
- Schedule write
- Holiday read and write
- Holiday read
- This command is used in order to write the setting of holiday
- The controller requests the monitor to write date time
- Holiday write
- Weekend read and write
- Weekend read
- Weekend write
- This command is used in order to write the setting of weekend
- The controller requests the monitor to write the setting of weekend
- Self diagnosis status read
- Self diagnosis
- Serial no model name read
- Serial no read
- Model name read
- Security lock control
- Security lock
- Daylight saving read write
- Daylight saving read
- Daylight saving write
- Firmware version read
- Firmware version
- Input name read
- Input name
- Input name write
- Input name reset
- Power save mode read
- Power save mode
- Power save mode write
- Auto power save time read
- Auto power save time write
- Security enable read
- Security enable
- Security enable write
- Lan mac address read
- Lan mac address
- Emergency contents display
- Emergency contents
- Emergency contents delete
- All data are subject to change without notice
Похожие устройства
-
Nec MultiSync V323-3Инструкция по эксплуатации -
Nec MultiSync V323-3Спецификация -
Nec MultiSync UN552VSИнструкция по эксплуатации -
Nec MultiSync UN552VSСпецификация -
Nec MultiSync UN552SИнструкция по эксплуатации -
Nec MultiSync UN552SСпецификация -
Nec MultiSync UN552VИнструкция по эксплуатации -
Nec MultiSync UN552VСпецификация -
Nec MultiSync UN552Инструкция по эксплуатации -
Nec MultiSync UN552Спецификация -
Nec MultiSync V323-3 PGИнструкция по эксплуатации -
Nec MultiSync V323-3 PGСпецификация
Узнайте, как эффективно читать и записывать данные активов с помощью протоколов. Подробное руководство по запросам и ответам для управления данными.