Nec MultiSync C501 [37/101] Power control procedure
Превью страниц
Страница 37 /
101
![Nec MultiSync C501 [37/101] Power control procedure](/views2/1375369/page37/bg25.png)
(37/104)
7. Power control procedure
7.1 Power status read
1) The controller requests the monitor to reply a current power status.
Header Message Check
code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'6'
STX-'0'-'1'-'D'-'6'-ETX BCC CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message Type is "Command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'1'-'D'-'6': Get power status command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor returns with the current power status.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h):Start of Message
'0'-'2' (30h, 32h): Reserved data
'0'-'0' (30h, 30h): Result code
00: No Error.
01: Unsupported.
'D'-'6'(44h, 36h): Display power mode code
'0'-'0' (30h, 30h): Parameter type code is "Set parameter".
'0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode
<Status>
0001: ON
0002: Stand-by (power save)
0003: Suspend (power save)
0004: OFF (same as IR power off)
ETX (03h): End of Message
Header Message Check
code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'1'-'2'
STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0'-
'0'-'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX
BCC CR
Содержание
129- Rev g5 index
- External control nec lcd monitor
- I application
- Lan control
- Ii preparation
- Connectors and wiring
- Rs 232c remote control
- Rs 232c remote control
- Lan control
- Iii communication specification
- Communication timing
- Communication parameter
- Set parameter
- Save current setting command reply
- Save current setting command
- Monitor controller
- Get parameter reply
- Get parameter
- Communication format
- Command reply
- Command
- Header block format fixed length
- Message block format
- Source address
- Soh reserved destination
- Op code set value etx
- Message length stx op code
- Message
- Header message check code bcc
- Delimiter
- Check code
- Address
- Message type
- Get current parameter from a monitor
- Get parameter reply
- Set parameter
- Set parameter reply
- Commands
- Save current settings
- Get timing report and timing reply
- Null message
- Typical procedure example
- Iv control commands
- How to change the backlight setting
- How to read the measurement value of the built in temperature sensors
- Picture
- Operation code op code table
- Brigtness
- Aspect
- Adjust
- Balance
- Advanced
- Equlizer
- Audio delay
- Schedule
- Schdule
- Terminal setting
- Multi input
- Custom detect
- Tile matrix
- Multi display
- Screen saver
- Power on delay
- Motion
- Ir lock setting
- Heat status
- Display protection
- Control
- Key lock setting
- Auto dimming
- System
- Room light sensing
- Power indicator
- Monitor information
- Backlight setting
- Power status read
- Power control procedure
- Power control
- Asset data read request and reply
- Asset data read and write
- Asset data write
- Date time read and write
- Date time read
- This command is used in order to write the setting of the date time
- The controller requests the monitor to write date time
- Date time write
- Schedule read and write
- Schedule read
- Schedule write
- Holiday read and write
- Holiday read
- This command is used in order to write the setting of holiday
- The controller requests the monitor to write date time
- Holiday write
- Weekend read and write
- Weekend read
- Weekend write
- This command is used in order to write the setting of weekend
- The controller requests the monitor to write the setting of weekend
- Self diagnosis status read
- Self diagnosis
- Serial no model name read
- Serial no read
- Model name read
- Security lock control
- Security lock
- Daylight saving read write
- Daylight saving read
- Daylight saving write
- Firmware version read
- Firmware version
- Input name read
- Input name
- Input name write
- Input name reset
- Power save mode read
- Power save mode
- Power save mode write
- Auto power save time read
- Auto power save time write
- Security enable read
- Security enable
- Security enable write
- Lan mac address read
- Lan mac address
- Emergency contents display
- Emergency contents
- Emergency contents delete
- All data are subject to change without notice
Похожие устройства
-
Nec MultiSync V323-3Инструкция по эксплуатации -
Nec MultiSync V323-3Спецификация -
Nec MultiSync UN552VSИнструкция по эксплуатации -
Nec MultiSync UN552VSСпецификация -
Nec MultiSync UN552SИнструкция по эксплуатации -
Nec MultiSync UN552SСпецификация -
Nec MultiSync UN552VИнструкция по эксплуатации -
Nec MultiSync UN552VСпецификация -
Nec MultiSync UN552Инструкция по эксплуатации -
Nec MultiSync UN552Спецификация -
Nec MultiSync V323-3 PGИнструкция по эксплуатации -
Nec MultiSync V323-3 PGСпецификация