Sharp PN-R496 [10/56] Specifications

Sharp PN-R496 [10/56] Specifications
8
E
Model PN-R706 PN-R606
Power requirement AC 100 - 240 V, 2.6 A, 50/60 Hz AC 100 - 240 V, 2.2 A, 50/60 Hz
Operating temperature * 32°F to 104°F (0°C to 40°C)
Operating humidity 20% to 80% (no condensation)
Power consumption 230 W 190 W
Dimensions inch (mm)
(excluding protrusions)
Approx. 62-3/16 (W) x 2-9/16 (D) x 36-1/8 (H)
(1579 x 65 x 918)
Approx. 53-1/8 (W) x 2-3/8 (D) x 30-1/2 (H)
(1349 x 60 x 775)
Weight lbs. (kg) Approx. 99.3 (45) Approx. 72.8 (33)
Model PN-R556 PN-R496 PN-R426
Power requirement AC 100 - 240 V, 2.0 A,
50/60 Hz
AC 100 - 240 V, 1.8 A,
50/60 Hz
AC 100 - 240 V, 1.5 A,
50/60 Hz
Operating temperature * 32°F to 104°F (0°C to 40°C)
Operating humidity 20% to 80% (no condensation)
Power consumption 175 W 155 W 135 W
Dimensions inch (mm)
(excluding protrusions)
Approx. 48-7/16 (W) x
2-1/4 (D) x 27-5/8 (H)
(1231 x 57 x 702)
Approx. 43-1/8 (W) x
2-1/4 (D) x 24-5/8 (H)
(1095 x 57 x 626)
Approx. 37-3/8 (W) x
2-1/4 (D) x 21-3/8 (H)
(949 x 57 x 543.5)
Weight lbs. (kg) Approx. 55.1 (25) Approx. 43 (19.5) Approx. 34.2 (15.5)
* When using the monitor laying at on a surface (when the monitor is tilted more than 20 degrees upward or downward from the perpendicular
in relation to a level surface), use the monitor at a temperature between 32°F (0°C) to 86°F (30°C).
Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP. In such
cases, please check the temperature condition specied by the optional equipments.
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specication changes for product improvement
without prior notice. The performance specication gures indicated are nominal values of production units. There may be some deviations from
these values in individual units.
Turning Power On/Off (Continued)
Specications
n
Date/time setting
If the time has yet to be set when the monitor is rst turned
on, the date/time setting screen appears. Set the date and
time.
DATE/TIME SETTING
//
OK:[ENTER] CANCEL:[RETURN]
: :
01 01 17
/
00 00
:/ 20
1. Press or to select the date and time, and press
or
to change the numerical values.
2. Press the ENTER button.
Be sure to set the date and time.
The date/time setting screen will close automatically if
no operation is performed for about 15 seconds. The
date and time can be set using DATE/TIME SETTING
from the SETUP menu when the date/time setting screen
disappears.
TIPS
Set the date in “Day/Month/Year” order.
Set the time on a 24-hour basis.
The clock is maintained by the internal battery.
If you already set the time but the date/time setting screen
appears when the power is turned on, the internal battery
may be exhausted. Please contact an authorized SHARP
servicing dealer or service center for assistance with
battery replacement.
Estimated service life of the internal battery: About 5 years
(depending on monitor operation)
The initial battery was inserted at the factory when the
monitor was shipped, so it may run out of power before its
expected operation life.

Содержание