Testo 875-1 [24/65] Evaluating images

Testo 875-1 [24/65] Evaluating images
6 Using the software
24
6.3.6. Accepting settings for multiple images
Copies the image settings of the currently selected thermal image
into all open thermal images.
1. Click on Thermal image settings .
- A dialogue box with the parameters is opened.
2. Select the parameters that you wish to accept for the other
infrared images and click on [OK].
- The settings are accepted for all open infrared images.
6.4. Evaluating images
IR images can be edited and evaluated in the individual document
windows below the work space.
6.4.1. Thermal image document window
The following functions are available in the Thermal image
document window:
Saving/exporting the infrared image
Copying the infrared image to the clipboard
Extract single images from a panoramic image
Export an image with detector resolution from a
SuperResolution image (standard imager resolution)
Rotating the infrared image
Specifying the readings for one pixel in an infrared image
Temperature correction in an infrared image area (adjust
emissivity and reflected temperature for the area)
Specifying a hotspot/coldspot for an infrared image area
Creating a histogram of an infrared image area
Creating a temperature profile for a line
Moving/deleting measuring points/range
Carrying out data agglomeration
Cancelling image overlay
Saving/exporting the infrared image
When exporting infrared images in BMP, JPG and PNG
format only the image data is exported, no readings.
If you wish to create a temperature table for the infrared
image, the infrared image must be saved in XLS/XLSX
format (Excel).
1. Click on Save thermal image .
- The Windows dialogue for saving files is opened.