Air-O-Swiss S450 [18/96] A switch on off

Air-O-Swiss S450 [18/96] A switch on off
18
en
• Makesurethattheunitisturnedoff.
• Removethetopcoveroftheunit(Note:formationof
condensation may occur after use on the inside of the
cover) and take the water tank from the unit by using
thetankhandle(9).
• Turnthewatertankupsidedown,unscrewthecapand
fillwithwater(9–10).
• Closethetankcapsecurely,placethetankintotheunit
andputthecoverbackon(11).
ECON-Mode
BypressingbuttonB,theAUTO-Modecanbechangedto
ECON-Mode(symbolK)andviseversa.IntheECON-Mode,
thedesiredrelativehumidity(rH)ispresetto45%.Theunit
choosestheappropriateoutputlevelLow«L»/Medium«M»
(symbolG),inordertoattainthevalueof45%rHasenergy-
efficiently as possible.
InECON-Mode,therHcanbechangedatanytimebyusing
button C; see C) Setting humidity level. If the output level
ischangedbyusingbuttonD,theECON-Modeturnsoff
andtheunitisoperatedmanually;seeD)Manualoperation.
BypressingbuttonBtwotimes,theECON-Modecanbe
reactivated.
C) Setting humidity level
The appliance is fitted with a hygrostat. This measures the
relative humidity and switches the appliance off automati-
callywhenthedesiredvalueisreached.Theinternalven-
tilation remains turned on, to ensure an accurate reading of
the relative humidity. If the relative humidity falls below the
desired value, humidification resumes automatically. The
desiredrelativehumiditycanbeadjustedinstepsof5%by
pressingbuttonB.Whileselectingthedesiredhumidityout-
put,thevaluedisplayisblinking.ThewordDESIREDappears
onthedisplay(symbolH).Afterafewseconds,thedisplay
automaticallychangestoshowthecurrentvalue(symbol
H).Uponreachingthedesiredrelativehumidity,thedisplay
showsDESIREDandCURRENT.
A relative humidity of between 40 and 60% is recom-
mended. The setting for the relative humidity ranges from a
minimumof30%toamaximumof70%relativehumidityor
«CO»continuousmode.
Symbol E2
Whenthedisplayshows«E2»,thecurrentrelativehumidity
hasreached90%.Forsafetyreasons,theapplianceswit-
ches off automatically. The appliance switches back on,
whentherelativehumidityfallsbelow85%.
A) Switch on/off
PressingbuttonAswitchestheapplianceeitheronoroff.
ButtonAisalsousedtostartthedecalcificationmode.See
thesectionabout«DecalcificationMode»(18–25).After
theunitisswitchedon,itisinAUTO-Mode(symbolJ).
B) AUTO- / ECON-Mode
AUTO-Mode:
Aftertheunitisswitchedon,itisinAUTO-Mode(symbolJ).
Thedesiredrelativehumidity(rH)ispresetto50%.Theunit
choosestheappropriateoutputlevelLow«L»/Medium«M»
/High«H»(symbolG),inordertoattainthevalueof50%rH
as quickly as possible.
InAUTO-Mode,therHcanbechangedatanytimebyusing
button C; see C) Setting humidity level. If the output level
ischanged by usingbutton D,theAUTO-Mode turns off
andtheunitisoperatedmanually;seeD)Manualoperation.
BypressingbuttonB,theAUTO-Modecanbereactivated.
Operation S450
ECON
AUTO
H
M
L
L
M
H
AUTO ECON
CURRENT
DESIRED
I
J K
L