Содержание

In models with covered terminal block tn mix models a cable supplied with a plug with your oven H05 V V F 3G 1 5 mm2 if a cable without a plug is provided together with your oven H05 V V F 3G 2 5 mm2 Take care to connect as below Brown cable L Live Blue coble N Neutral Green Yellow coble E Earth v If your oven is supplied without supply cord use schema 1 to choose supply cord and use schema ll for installation ofcord The cable length should be max 2m long for isolation safety kIkkk Open the terminal block cover 1 Connect the supply cable according to wiring diagram on the rear cover Assembly the terminal block cover to its place The mains cable must pass through the coble clamp 2 to the cooker than 150 mm and should be of heat resistant Fix the supply cable to main body with two screw via cable tightener 2 Your oven is suitable for single and three phase connection material Leave at least 750 mm clearance above the hotplates The mains cable should be routed away from the appliance and in particular ventilation slots the vent outlet and should not be obstructed when The appliance should be located on a level surface pushed in to position between the appliance and the wall and or cabinet Connection Type Voltage Monophase 220 230 Adjacent side walls above the appliance must not be nearer Three phase Two phase with Neutral with Neutral 380 400 415 V 380 400 415 V The two front feet can be adjusted as required To ensure that your appliance is standing level adjust the two front feet by turning clockwise 240 V Supply cord type 3x2 5 mm2 5x2 5 mm2 4x2 5 mm2 max 2m long H05 V V F H05 V V F H05 V V F Schema I 4 or counterclockwise until the product is in firm contact with the floor