Fluke 754 [4/12] It s easy to calibrate and maintain hart instrumentation with one powerful tool
![Fluke 754 [4/12] It s easy to calibrate and maintain hart instrumentation with one powerful tool](/views2/1436073/page4/bg4.png)
It’s easy to calibrate and maintain
HART instrumentation with one powerful tool.
With the 754 DPC, you can:
• Generate precision electrical, temperature, or
pressure signals for analog stimulus or sensor
simulation.
• Simultaneously measure electrical, temperature,
or pressure signals from transmitter output.
• Determine type, manufacturer, model, tag ID by
interrogating HART devices.
• Read HART PV function and smart transmitter
digital output while measuring analog mA output.
• Read and write HART configuration functions to
make field adjustments to PV range points, damping,
and other top-level configuration settings.
• Change sensor configuration on supported
temperature transmitters.
• Re-label smart transmitters by reading and writing
HART tag and message fields.
• Clone additional transmitters by reading and
storing basic HART configurations.
• Perform automated HART sensor trim and output
trim for selected devices in conjunction with
As Found/As Left tests.
• Perform loop test with simultaneous analog and
digital mA readout.
• Address new, fast, pulsed-excitation smart
transmitters and PLCs.
• Fluke Calibration dry block temperature sources and
portable temperature baths.
4 Fluke Corporation 750 Series Brochure
+
–
Содержание
- Work smarter work faster 1
- Bonus feature available with product registration 2
- Fluke 750 series documenting process calibrators 2
- Get the knowledge straight from the product expert in these process tools videos 2
- Online now at www fluke com ptoolsvideos 2
- Work smarter work faster 2
- Fluke 750 series documenting process calibrators calibrators as versatile as you are 3
- Fluke 754 hart documenting process calibrator get hart ability 3
- It s easy to calibrate and maintain hart instrumentation with one powerful tool 4
- Hart applications 5
- Fluke 789 processmete 6
- Automatically record and document your work 7
- Ac voltage measurement 8
- Confidence interval k 3 8
- Dc current measurement 8
- Dc current output 8
- Dc voltage measurement 8
- Dc voltage output 8
- Frequency measurement 8
- Frequency sourcing 8
- Measurement function specifications 8
- Resistance measurement 8
- Resistance sourcing 8
- Sourcing simulation function specifications 8
- Allowance for traceability fluke specs are not relative specs but total specs 9
- C compensation factors are provided to permit specified use of the calibra tors over a wide 10 c to 50 c range 9
- Confidence interval k 3 9
- For example fluke specifications use a 3 sigma confidence interval k 3 this means that 99 of measurements will remain in specification over the stated period of time other manufacturers use a 2 sigma confidence interval k 2 this means that 95 of measurements will remain in specification over the stated period of time so one in 20 instruments are statistically likely to fail to perform to their specifications 9
- Including an allowance for uncertainty of standards that provide traceability to national standards 9
- Reference uncertainty performance of a calibrator at 23 c 3 c at the time it is 9
- Specifications must be carefully considered when comparing calibrators from different vendors 9
- Specs to limit your calibration support costs you choose your cal interval based upon the performance you need 9
- Temperature fluke process calibrator specs reflect performance from 18 c to 9
- Temperature measurement and simulation specifications 9
- Temperature resistance temperature detector 9
- Temperature thermocouples 9
- The most important components of a process calibrator specification are 9
- Time fluke 750 series calibrators are delivered with both one year and two year 9
- Verified by the manufacturer this specification does not include the effects of time and temperature two of the largest components of calibrator error 9
- Why you can depend on fluke calibrator specifications 9
- Pressure module specifications 10
- Pressure specifications 10
- The fluke family of 50 pressure modules 10
- All specifications in of full span specifications reflect a confidence interval of 95 11
- Pressure module specifications cont 11
- Fluke keeping your world up and running 12
- General specifications 12
- Ordering information 12
Похожие устройства
- Fluke 754 DPC TRACK _ Руководство по эксплуатации
- Fluke 754 Pressure Calibration APPLICATIONS AND SOLUTIONS
- Fluke 754 Приложение к Руководству по эксплуатации
- Fluke 754 Начало работы
- Fluke 754 DPCTrack2 _ Руководство по эксплуатации
- Fluke 754 Руководство по калибровке
- Fluke 753 DPC TRACK _ Руководство по установке
- Fluke 753 Приложение к руководству по калибровке
- Fluke 753 Calibration and documentation for process manufacturing_ Costs, benefits and feasibility
- Fluke 753 DPCTrack2 _ Начало работы
- Fluke 753 Начало работы
- Fluke 753 Положение об энергозависимости памяти
- Fluke 753 Руководство по калибровке
- Fluke 753 750 Series Brochure
- Fluke 753 DPCTrack2 _ Руководство по эксплуатации
- Fluke 753 Pressure Calibration APPLICATIONS AND SOLUTIONS
- Fluke 726 Precision Multifunction Process Calibrator
- Fluke 726 Приложение к Руководству по эксплуатации
- Fluke 726 Паспорт безопасности
- Fluke 726 Руководство по калибровке
Скачать
Случайные обсуждения