Zkteco TS2200 [5/11] Connection diagram of the standalone access control device
Содержание
- Ts2200 series tripod turnstile user manual 1
- Arm installation and equipment testing 2
- Arm installation method 2
- Technical specifications 2
- Equipment installation 3
- Installation conditions 3
- Power on test before the installation of device 3
- Cabling 4
- Installation 4
- Cable diagram 5
- Connection diagram of the standalone access control device 5
- Function description of the turnstile control board 5
- 3 4 5 6 7 8 6
- Dip ki switch configuration 6
- Equipment precautions and maintenance 7
- Maintenance 7
- Precaution 7
- Troubleshooting 8
- Attachment 1 default factory settings 9
- Attachment 3 connection diagram of mainboard and secondary board 11
- J4 left direction indicator 11
- Mainboard 11
- Secondary board 11
- The connection of mainboard and secondary board 11
- This is a class a product in a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 11
Похожие устройства
- Zkteco TS2200 Брошюра
- Zkteco TS5000A Руководство по установке
- Zkteco TS5000A Инструкция по эксплуатации(ENG)
- Zkteco TS5000A Брошюра
- Zkteco FBL1000 Руководство по установке
- Zkteco FBL1000 Инструкция по эксплуатации(ENG)
- Zkteco FBL1000 Брошюра
- Silter Super mini 2000M-1 Инструкция по эксплуатации
- Silter Super mini 2000M-1 Инструкция по эксплуатации
- Silter Super mini 2000 Инструкция по эксплуатации
- Silter Super mini 2000 Инструкция по эксплуатации
- Silter Super mini 2002 Инструкция по эксплуатации
- Silter Super mini 2002 Инструкция по эксплуатации
- Silter Super mini 2035 Инструкция по эксплуатации
- Silter Super mini 2035 Инструкция по эксплуатации
- Silter Super mini 2005Е Инструкция по эксплуатации
- Silter Super mini 2005Е Инструкция по эксплуатации
- Silter Super mini 2075 Инструкция по эксплуатации
- Silter Super mini 2075 Инструкция по эксплуатации
- Silter Super MX 1/0 Инструкция по эксплуатации
4 Cable Diagram 4 1 Function Description of the Turnstile Control Board If you are using TS2211 orTS2222 all the connections between access control and turnstile control boards are done in factory Just plug in communication cable to access controller and do the setting If you are using TS22OO you need to connect access control system to the main board please check the content in this chapter carefully Warning The third party access control system lock relay trigger time should be 1 second or less than 1 second Figure 4 1 Descriptions J2 Counter To connect a LED screen and display the number of people passed that isgenerated by the push oftripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate whether this passage is allowed to pass J3 Indicator top To connect a LED screen and indicate if user verification is successful and whether it is able to pass J NC2 Disbled Turnstile Short circuit NC1 and GND the turnstile is disabled that is to say the turnstile is locked by force J7 Opening Signal Input To receive relay signal and open the turnstile Short circuit K1 and GND left passing is allowed short circuit K2 and GND right passing sallowed J6 External Alarm Short circuit ALARM 1 and GND and the turnstile is disabled locked and the alarm is ringing in case there are emergencies J6 Drop Arm Short circuit DOW and GND the arm is dropped down by force in case there are fires or other emergencies 4 2 Connection Diagram of the Standalone Access Control Device Note The lock driving duration of standalone access control device needs to be set to 1s or Os and the door sensor needs to be set to None Standalone Access Control Device Figure 4 2 4