Fluke 1745 [59/72] Power supply

Fluke 1745 [59/72] Power supply
Power Quality Logger
Technical Specifications
45
Environmental Specifications
Working temperature
range
-10°C to +55°C
Operating temperature
range
0°C to +35°C
Storage temperature range -20°C to +60°C
Reference temperature
range
23°C ± 2 K
Relative humidity 10 to 90 %, no condensation
Housing Robust, compact housing of CYCOLOY
Protection IP50 per EN 60529
Safety EN 61010-1 600 V CAT III, 300 V CAT IV
pollution degree 2, double insulation
Type test voltage 5.2 kV AC, 50 Hz / 60 Hz, 5 s
EMC
Emission IEC/EN 61326-1, EN 55022
Immunity IEC/EN 61326-1
Power Supply
Functional range 88 to 660 V RMS AC absolute, 50 Hz / 60 Hz
Safety EN 61010-1 600 V CAT III, 300 V CAT IV,
pollution degree 2, double insulation
Fuse Power supply fuse can be replaced only in service
facility. Supply can be connected in parallel to
measuring inputs (up to 660 V RMS AC).
Power consumption 5 W
Memory capacity 8 MB Flash-EPROM
Intervals > 10000 intervals, > 70 days with 10 min intervals
Events > 13000

Содержание