Epson Stylus Pro XL+ [17/573] Esc c set page length in defined unit

Epson Stylus Pro [17/573] Esc c set page length in defined unit
C-10 Individual Command Explanations
ESC ( C Set page length in defined unit
ESC/P 2
Format
ASCII ESC ( C nL nH mL mH
Hex 1B 28 43 nL nH mL mH
Decimal 27 40 67 nL nH mL mH
Parameter range
nL = 2, nH = 0
0 < ((mH × 256) + mL) × (defined unit) 22
Function
Sets the page length in the specified number of units—previously defined with the ESC ( U
command—according to the following formula:
(page length) =((mH × 256) + mL) × (defined unit)
mH = INT
page length
definedunit
( )
( )
×
1
256
mL = MOD
page length
definedunit
( )
( )
×
1
256
Default
Depends on default-setting mode or DIP-switch setting
Notes
This command is available only on printers featuring ESC/P 2.
Set the page length before paper is loaded or when the print position is at the top-of-
form position. Otherwise, the current print position becomes the top-of-form position
(this results in undesirable contradictions between the actual and logical page settings).
Setting the page length cancels the top and bottom-margin settings.
Changing the defined unit does not affect the current page-length setting.
Printers not featuring this command
All non-ESC/P 2 printers
Model-dependent variations
None
Related topics
ESC ( U, ESC ( c, ESC C, FF, LF, ESC N, Set the Print Area, Setting page length