Emotron FLD48-061-54 [29/68] Please refer to the chapter technical data section 8 page 61

Emotron FLD48-4P1-2Y [29/68] Please refer to the chapter technical data section 8 page 61
CG Drives & Automation, 01-6142-01r0 Installation 25
3.4.2 Fuse data
Please refer to the chapter Technical data, section 8.7, page
61.
3.4.3 Cable connection data for mains, motor and PE cables according to IEC
ratings
NOTE: The dimensions of the power terminals used in the
cabinet drive models 300 to 3K0 can differ depending
on customer specification.
Table 14 Cable connector range and tightening torque for Emotron FLD48 and FLD52, according to IEC ratings.
Model
Frame
size
Cable cross section connector range
Cable type
Mains and motor Brake PE
Cable area
mm
2
Tightening
torque
Nm
Cable area
mm
2
Tightening
torque
Nm
Cable area
mm
2
Tightening
torque
Nm
FLD##-003
B 0.5 - 10 1.2-1.4 0.5 - 10 1.2-1.4 1.5 - 16 2.6
Copper (Cu)
75°C
FLD##-004
FLD##-006
FLD##-008
FLD##-010
FLD##-013
FLD##-018
FLD48-025
C2 4 - 25 2 4 - 25 2 4 - 25 * 4.3
FLD48-030
FLD48-036
FLD48-045
FLD48-058
FLD##-026
C
2.5-16
stranded
2.5-25 solid
1.2-1.4
2.5-16
stranded
2.5-25 solid
1.2-1.4
6-16 stranded
6-25 solid
1.2-1.4
FLD##-031
FLD##-037
FLD##-046
FLD48-072 D2 0.75 - 50 3.3 0.75 - 50 3.3
10 - 70* 4.3FLD48-088
D2 16 - 50 7. 9 16 - 50 7. 9
FLD48-105
FLD##-061
D
10-35
stranded
10-50 solid
2.8-3
10-35
stranded
10-50 solid
2.8-3
16-35
stranded
16-50 solid
2.8-3
FLD##-074
FLD48-142
E2
16- 150
31 (for
16-34 mm
2
)
42 (for
35-150 mm
2
)
16 - 120
31 (for
16-34 mm
2
)
42 (for
35-120
mm
2
)
16- 150
16 - 185 **
31 (for
16-34 mm
2
)
42 (for
35-150 mm
2
)
10 **
FLD48-171
FLD48-090
E
FLD48-109
FLD48-146
FLD48-175

Содержание

Скачать