Yaskawa CIMR-UU2A0042A [536/644] The following tables show parameters and default settings that change with the drive model selection o2 04 and drive duty selection c6 01 parameter numbers shown in pa...

Yaskawa CIMR-UU4A0216A [536/644] The following tables show parameters and default settings that change with the drive model selection o2 04 and drive duty selection c6 01 parameter numbers shown in parenthesis are valid for motor 2
B.18 Defaults by Drive Model and Duty Rating ND/HD
The following tables
show parameters and default settings that change with the drive model selection (o2-04) and drive duty
selection (C6-01). Parameter numbers shown in parenthesis are valid for motor 2.
Table B.9 200 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
No. Name Unit Default Settings
Drive Model
2o0028 2o0042 2o0054 2o0068
C6-01 Drive Duty Selection HD ND HD ND HD ND HD ND
o2-04 Drive Model Selection Hex. 6A 6B 6D 6E
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
5.5 (7.5) 7.5 (10) 7.5 (10) 11 (15) 11 (15) 15 (20) 15 (20) 18.5 (25)
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 100 100 100
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value 94.75 72.69 72.69 70.44 70.44 63.13 63.13 57.87
C5-17 (C5-37) Motor Inertia
kgm
2
0.026 0.037 0.037 0.053 0.053 0.076 0.076 0.138
C6-02 Carrier Frequency Selection 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 19.6 26.6 26.6 39.7 39.7 53 53 65.8
E2-02 (E4-02) Motor Rated Slip Hz 1.5 1.3 1.3 1.7 1.7 1.6 1.6 1.67
E2-03 (E4-03) Motor No-Load Current A 5.1 8 8 11.2 11.2 15.2 15.2 15.7
E2-05 (E4-05) Motor Line-to-Line Resistance Ω 0.399 0.288 0.288 0.23 0.23 0.138 0.138 0.101
E2-06 (E4-06) Motor Leakage Inductance % 18.2 15.5 15.5 19.5 19.5 17.2 17.2 20.1
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 172 262 262 245 245 272 272 505
E5-01 Motor Code Selection (for PM Motors) Hex. 120A 120A 120B 120B 120D 120D 120E 120E
L2-02 Momentary Power Loss Ride-Thru Time s 0.7 0.8 0.8 0.9 0.9 1 1 1
L2-03
Momentary Power Loss Minimum
Baseblock Time
s 0.3 0.3 0.3 0.3 0.3 0.6 0.6 0.6
L2-04
Momentary Power Loss Voltage Recovery
Time
s 150 150 150 150 150 150 150 150
L8-02 Overheat Alarm Level °C 130 130 130 130 130 130 130 130
L8-35 Installation Method Selection 0 0 0 0 0 0 0 0
L8-38 Carrier Frequency Reduction Selection 1 1 1 1 1 1 1 1
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10
n5-02 Motor Acceleration Time s 0.168 0.175 0.175 0.265 0.265 0.244 0.244 0.317
Table B.10 200 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
No. Name Unit Default Settings
Drive Model
2o0081 2o0104 2o0130 2o0154
C6-01 Drive Duty Selection HD ND HD ND HD ND HD ND
o2-04 Drive Model Selection Hex. 6F 70 72 73
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
18.5 (25) 22 (30) 22 (30) 30 (40) 30 (40) 37 (50) 37 (50) 45 (60)
b3-04 V/f Gain during Speed Search % 100 100 100 80 80 80 80 80
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value 57.87 51.79 51.79 46.27 46.27 38.16 38.16 35.78
C5-17 (C5-37) Motor Inertia
kgm
2
0.138 0.165 0.165 0.220 0.220 0.273 0.273 0.333
C6-02 Carrier Frequency Selection 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 65.8 77.2 77.2 105 105 131 131 160
E2-02 (E4-02) Motor Rated Slip Hz 1.67 1.7 1.7 1.8 1.8 1.33 1.33 1.6
E2-03 (E4-03) Motor No-Load Current A 15.7 18.5 18.5 21.9 21.9 38.2 38.2 44
B.18 Defaults by Drive Model and Duty Rating ND/HD
536
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual