Indesit KJ3G2/R [16/44] Kj3g2 r

Indesit KJ3G2/R [16/44] Kj3g2 r
16
GB
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
S
S
R
A
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x39x44 cm
Volume
58 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 18 cm
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Table of burner and nozzle specifications
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
KJ3G2/R
Table 1 Liquid Gas Natural Gas
 





!""

#
$
!""

#

!""

#

! %&&     
#
'$%
 ( ) + 2) 62 6+ 62 62: +( 62:
;#
<&;
)> ? + ( ) (2 (: + 2 2 2
@D
;@
>  + ( >6 )( ) ): ?> 2 ?>
EF 6  +2+? :2 +> +( ) ? + ?
;

!G
<G
<DG
62(
6
(>
()
6>
+>
6
)
6>
(
:H>
2

Содержание

Похожие устройства

GB 5 Turn the knob from the MAX position to the MIN position quickly or open and shut the oven door making sure that the burner is not extinguished TECHNICAL DATA Oven dimensions HxWxD Volume Useful measurements relating to the oven compartment Power supply voltage and frequency 34x39x44 cm 581 width 42 cm depth 44 cm height 18 cm see data plate may be adapted for use with any type of gas shown on the data plate which is located inside the flap or after the oven compartment has been opened on the left hand wall inside the oven _________________________ EC Directives 2006 95 EC dated 12 12 06 Low Voltage and subsequent amendments 2004 108 EC dated 15 12 04 Electromagnetic Compatibility and subsequent amendments 2009 142 EC dated 30 11 09 Gas and subsequent amendments 93 68 EEC dated 22 07 93 and subsequent amendments 2002 96 EC 1275 2008 Stand by Off mode Burners Table of burner and nozzle specifications Table 1 Burner Liquid Gas Diameter mm Natural Gas Thermal Power kW p c s By Pass 1 100 Nozzle 1 100 Flow g h Nozzle 1 100 Nominal Reduced mm mm mm Flow l h Nozzle 1 100 Flow l h mm Fast Large R 100 3 00 0 7 41 87 218 214 128 286 143 286 Semi Fast Medium S 75 1 90 0 4 30 70 138 136 104 181 118 181 Auxiliary Small A 51 1 00 0 4 30 52 73 71 76 95 80 95 2 00 1 0 48 49 68 145 143 107 190 114 190 28 30 20 35 37 25 45 Oven Supply Pressures 16 Nominal mbar Minimum mbar Maximum mbar At 15 Cand 1013 mbar drygas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m3 20 17 25 KJ3G2 R 13 6 5 18

Скачать