Daikin EWADC16BJYNN [23/346] Esie07 04 general outline

Daikin EWAD900BJYNN/Q [23/346] Esie07 04 general outline
ESIE07-04 General Outline
Part 1 – System Outline 1–11
3
1
4
5
Notes: (1) Cooling capacity and power input are based on 12/7 °C entering/leaving water temp. and 35°C air ambient
temp.
Power input is for compressor only.
(2) For cooling capacity in the middle of 868kW and 945kW, select EWAD-BJYNN/A unit.
Notes: (1) Cooling capacity and power input are based on 12/7 °C entering/leaving water temp. and 35°C air ambient
temp.
Power input is for compressor only.
(2) For cooling capacity in the middle of 1296kW and 1457kW, select EWAD-BJYNN/A unit.
Weight and dimensions
Standard unit shipping weight kg 7910 8190 8190 8780 8930
Standard unit operating weight kg 8330 8610 8610 9190 9340
Unit length mm 7400 8270 8270 9200 9200
Unit width mm 2230 2230 2230 2230 2230
Unit height mm 2520 2520 2520 2520 2520
Model EWAD-BJYNN with OPLN
Unit size Note (2) 950 C10 C11 C12 C13
Model EWAD-BJYNN with OPLN
Unit size C14 Note (2) C15 C16 C18
Cooling capacity (1) kW 1296 1457 1553 1735
Power input (1) kW 456 546 573 610
COP 2.84 2.67 2.71 2.84
Screw compressors 3 4 4 4
Refrigerant circuits 3 4 4 4
Refrigerant charge R-134a kg 186 228 248 248
Oil charge kg 60 80 80 80
Min % of capacity reduction % 8.3 6.25 6.25 6.25
Condenser fans
No. of fans / nominal power fan kW 18/1 22/1 24/1 24/1
Fan speed rpm 680 680 680 680
Diameter mm 800 800 800 800
Total air flow m3/s 73.6 89.0 97.1 98.0
Evaporator
Evaporators / water volume N°/l 1/402 2/254+246 2/246+246 2/246+246
Max operating pressure bar 10.5 10.5 10.5 10.5
Water connection diameter mm 219.1 168.3 168.3 168.3
Condenser coil
Coil type Lanced fins - internally spiral wound tubes
Weight and dimensions
Standard unit shipping weight kg 9080 10032 11112 11312
Standard unit operating weight kg 9490 10504 11620 11820
Unit length mm 9200 11000 11900 11900
Unit width mm 2230 2230 2230 2230
Unit height mm 2520 2520 2520 2520

Содержание