AXIOMET AX-6003P [3/10] Operation instructions

AXIOMET AX-3003P [3/10] Operation instructions
1. Power switch
2. Function key and Numeric keypad
3. OCP indicator
4. OVP indicator
5. CV indicator
6. CC indicator
7. LCD display
8. Rotary knob
9. Positive output terminal
10. Ground terminal
11. Negative output terminal
Rear Panel
1. Cooling fan
2. USB interface
3. AC110/220V power selection switch
4. Power cord / fuse socket
There are four indicators on both sides of the screen, as
shown above.
CV indicator: The CV light turns green to indicate the in-
strument is in the CV mode.
CC indicator: The CC light turns red to indicate the instru-
ment is in the CC mode.
OVP indicator: The OVP light turns green to indicate the
over voltage protection function is on.
OCP indicator: The OCP light turns red to indicate the over
current protection function is on.
4. Operation Instructions
4.1. Basic Operations
The applied Voltage/Current Unit for this series
instruments is Volt and Amp.
The factory setting is in panel operation mode that
enable user to operate the instruments directly from
panel control knob. Besides, when the remote controller
is on line, the Lock key light turns on and the operation
can only be proceed through it. At this time, all the
panel operations are closed unless the key [Lock] is
pressed, but the Output is still working. Whenever the
power is reset, the output will be at OFF status and the
operation is through front panel operation mode.
When users operate the power supply with dual range,
during the switch process, the output is at OFF
automatically. And if the original setting value is more
than the maximum output range after switch, the setting
value will be modified automatically to the maximum
output value after switch
When the Output key light turns on, the CV or CC
indicator at the right side of the LCD represents the
instrument is in the CV or CC mode and the LCD
displays the output measurement value.
The output of power supplies is always at OFF status
after power on.
5. Numeric Keypad Input
If an option is selected, you can input the parameters by us-
ing the numeric keys. There are ten numeric keys for data
input. The input method is the shift input from right to left.