MEAN WELL RCP-2000-48 [3/5] Rcp 2000

MEAN WELL RCP-2000-48 [3/5] Rcp 2000
PFC fosc : 110KHz
PWM fosc : 90KHz
Block Diagram
2000W Front End Power Supply
R CP-200 0
s eri es
File Name:RCP-2000-SPEC 2013 -11-01
LIMITING
AC TIVE
CURRENT
INRUSH
CONTROL
I/P
RECTIFIERS
&
FILTER
SWITCHING
POWER
RECTIFIERS
FILTER
EMI
PWM
CIRCUIT
DETEC TION
POWER
AUX
&
PFC
FILTER
&
12V/0.8A
AU X POWER
PFC
CONTROL
5V/0 .3A
AC-OK
MCU
DETECTION
CIRCUIT
O.V.P.
MCU
O.T.P.
DA/DB
PV
DC-O K
T-Ala rm
SDA/SCL
ON/OFF
PM BUS
FAN FAIL
FAN
+V
-S
+S
RECTIFIERS
ORING
FET
-V
ORING FET
CONTROL
TRANSCEIVERS
DATA
IS OLATION
Function Description of CN501
Pin No.
1,2,3,4
10
9
5,6,7,8
12,13
17
22
23
24
25
26
28
31
32
33
34
Note1: Non-isolated signal, referenced to the output terminals (-V).
Note2: Isolated signal, referenced to GND-AUX.
11
14
15
27
29
30
16,18,19,
20,21
Function
+V
+V
-V
-V
DA,DB
ON/OFF
NC
SDA
SCL
AC-OK
DC-OK
FAN-FAIL
GND-AUX
FG
AC/L
AC/N
PV
+S
-S
T-ALARM
+5V-AUX
+12V-AUX
A0,A1,A2,
A3,A4
Description
Positive output voltage
+V Signal
-V Signal
Negative output voltage.
Differential digital signal for parallel control. (Note.1)
The unit can turn the output on and off by electrical signal or dry contact between ON/OFF and +5V-AUX. (Note.2)
Short (4.5 ~ 5.5V) : Power ON ; Open (0 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.
Not use.
Serial Data used in the PMBus interface. (Note.2)
Serial Clock used in the PMBus interface. (Note.2)
Low (0 ~ 0.5V) : When the input voltage is 87Vrms.
High (4.5 ~ 5.5V) : When the input voltage in 75Vrms . The maximum sourcing current is 10mA and only for output. (Note.2)
High (4.5 ~ 5.5V) : When the Vout 80% 5%. ±
Low (0 ~ 0.5V) : When Vout 80% 5%. The maximum sourcing current is 10mA and only for output. (Note.2) ±
High : When the internal fan fail. (4.5 ~ 5.5V)
Low : When the internal fan is normal. (0 ~ 0.5V) The maximum sourcing current is 10mA and only for output(Note.2)
Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).
AC Ground connection.
AC Line connection.
AC Neutral connection.
Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1)
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be
High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.(4.5 ~ 5.5V)
Low : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. (0 ~ 0.5V) The maximum sourcing
current is 10mA and only for output(Note.2)
Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin 31). The maximum load current is 0.3A. This output has the
Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 31). The maximum load current is 0.8A. This output has
PMBus interface address lines. (Note.1)
twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
built-in "Oring diodes" and is not controlled by the remote ON/OFF control.
the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.
Скачать