MEAN WELL XLG-200-L-A [3/9] Xlg 200

MEAN WELL XLG-200-L-A [3/9] Xlg 200
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ. RANGE
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.5
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
MTBF
DIMENSION
OTHERS
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
2.2A / 115VAC 1.1A / 230VAC 0.9A / 277VAC
<0.75mA / 277VAC
Compliance to EN55015, EN61000-3-2 Class C ( ); EN61000-3-3@ load50%
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 6 KV, Line-Line 4KV)(10K/6KV option)
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH non-condensing
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
749.06Khrs min. Telcordia SR-332(Bellcore) ; 200.67Khrs min. MIL-HDBK-217F (25)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
94% 93%
EMC IMMUNITY
EMC EMISSION
COLD START 65A(twidth=550 s measured at 50% Ipeak) at 230VAC;μ Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
CONSTANT CURRENT REGION Note.2
PACKING
0.85Kg;16pcs/14.2Kg/0.72CUFT
NOTE
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC
Hiccup mode or Constant current limiting,recovers automatically after fault condition is removed
(Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section)
100 ~ 305VAC 142VDC ~ 431VDC
OPEN CIRCUIT VOLTAGE (max.)
301 ~ 360V
61 ~ 78V
Shut down output voltage, re-power on to recovery
TEMP. COEFFICIENT
±0.03%/ (0 ~ 60)
WORKING TEMP.
Tcase=-40 ~ +90(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase=+90
PF 0.97 / 115VAC, PF 0.95 / 230VAC full load , PF0.92 / 277VAC at
(Please refer to " " )Power Factor Characteristic section
THD< 10% (@ load50% at 115VAC/230VAC ,@load75% at 277VAC)
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
CURRENT RIPPLE 3.0%(@ Load50% rated voltage)
CURRENT TOLERANCE ±5%
SET UP TIME Note.4 500ms/230VAC, 1200ms/115VAC
STANDBY
POWER CONSUMPTION
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;
GB19510.1,GB19510.14; EAC TP TC 004;IP67 approved
199*63*35.5mm (L*W*H)
350~1050mA
700mA
200W
700~1050mA
142 ~285V
300V
XLG-200 -L-
200W
3500mA
27 ~ 56V
60V
1750~5550mA
3500~5550mA
XLG-200 -H-
Hiccup mode,recovers automatically after fault condition is removed
Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version)
INPUT OVER VOLTAGE Note.5
can survive input voltage stress of 440Vac for 48 hours
1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedcurrentand25 ofambienttemperature.
2.Pleasereferto"DRIVINGMETHODSOFLEDMODULE".
3.De-ratingmaybeneededunderlowinputvoltages.Pleasereferto“STATICCHARACTERISTIC”sectionsfordetails.
4.Lengthofsetuptimeismeasuredatfirstcoldstart.TurningON/OFFthedrivermayleadtoincreaseofthesetuptime.
5.InputovervoltageonlyforXLG-200Iseries,andIserieswithoutUL/CSAcertificate.
6.Thedriverisconsideredasacomponentthatwillbeoperatedincombinationwithfinalequipment.SinceEMCperformancewillbeaffectedbythe
completeinstallation,thefinalequipmentmanufacturersmustre-qualifyEMCDirectiveonthecompleteinstallationagain.
7.Thisseriesmeetsthetypicallifeexpectancyof>50,000hoursofoperationwhenTcase,particularlytcpoint(orTMP,perDLC),isabout70 orless.
8.PleaserefertothewarrantystatementonMEANWELL'swebsiteathttp://www.meanwell.com
9.Theambienttemperaturederatingof3.5 /1000mwithfanlessmodelsandof5 /1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).
10.TofulfillrequirementsofthelatestErPregulationforlightingfixtures,thisLEDdrivercanonlybeusedbehindaswitchwithoutpermanentlyconnectedto
themains.
11.ProductssourcedfromtheAmericasregionsmaynothavetheCCC/PSE/BIS/KClogo.PleasecontactyourMEANWELLsalesformoreinformation.
12.ForanyapplicationnoteandIPwaterprooffunctioninstallationcaution,pleasereferourusermanualbeforeusing.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
13.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.
14.To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
Adjustable for A/AB-Type only (via the built-in potentiometer)
200W Constant Power Mode LED Driver
XLG-200 series
File Name:XLG-200-SPEC 2019-07-04
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Standard
EN61000-3-2 ,GB/T17625.1
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level/Note
-----
-----
Class C @load≥50%
-----
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EMC IMMUNITY
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed)
Скачать