Daikin RXYQ26PY1 [4/398] Troubleshooting by indication on the remote controller 20

Daikin RXYQ48PHY1 [4/398] Troubleshooting by indication on the remote controller 20
Si34-601A
Table of Contents iii
2.4 Operation of The Remote Controller’s Inspection /
Test Operation Button ..........................................................................209
2.5 Remote Controller Service Mode .........................................................210
2.6 Remote Controller Self-Diagnosis Function .........................................212
3. Troubleshooting by Indication on the Remote Controller ....................220
3.1 A0” Indoor Unit: Error of External Protection Device ...........................220
3.2 A1” Indoor Unit: PC Board Defect.........................................................221
3.3 A3” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......222
3.4 A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................224
3.5 A7” Indoor Unit: Malfunction of Swing Flap Motor (M1S) .....................225
3.6 A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E)........................................................227
3.7 AF” Indoor Unit: Drain Level above Limit..............................................229
3.8 AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........230
3.9 C4” Indoor Unit: Malfunction of Thermistor (R2T)
for Heat Exchanger ..............................................................................231
3.10 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........232
3.11 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........233
3.12 CJ” Indoor Unit: Malfunction of Thermostat Sensor
in Remote Controller ............................................................................234
3.13 E1” Outdoor Unit: PC Board Defect ......................................................235
3.14 E3” Outdoor Unit: Actuation of High Pressure Switch ..........................236
3.15 E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................238
3.16 E5 Outdoor Unit: Inverter Compressor Motor Lock.............................240
3.17 E6 Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............242
3.18 E7 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................243
3.19 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................246
3.20 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................248
3.21 F6 Outdoor Unit: Refrigerant Overcharged.........................................249
3.22 H7 Outdoor Unit: Abnormal Outdoor Fan Motor Signal.......................250
3.23 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....251
3.24 J2 Outdoor Unit: Current Sensor Malfunction ....................................252
3.25 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31~33T) .....................................................................................253
3.26 J5” Outdoor Unit: Malfunction of Thermistor (R2T), (R7T)
for Suction Pipe ....................................................................................254
3.27 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................255
3.28 J7” Outdoor Unit: Malfunction of Liquid Pipe Thermistor (R6T)...........256
3.29 J9” Outdoor Unit: Malfunction of Subcooling Heat Exchanger
Gas Pipe Thermistor (R5T) ..................................................................257
3.30 JA” Outdoor Unit: Malfunction of High Pressure Sensor......................258
3.31 JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................259
3.32 L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................260
3.33 L5” Outdoor Unit: Inverter Compressor Abnormal ...............................262
3.34 L8” Outdoor Unit: Inverter Current Abnormal.......................................264
3.35 L9” Outdoor Unit: Inverter Start up Error..............................................266
3.36 LC” Outdoor Unit: Malfunction of Transmission Between Inverter
and Control PC Board ..........................................................................268
3.37 P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................271