Daikin RXQ5M9W1B [4/32] 1 technical specifications
![Daikin RXQ5M9W1B [4/32] 1 technical specifications](/views2/1715461/page4/bg4.png)
3
1
• VRVII Systems • Outdoor Units
3
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B
Operation
Range
Cooling Min °CDB -5.0 -5.0 -5.0
Max °CDB 43.0 43.0 43.0
Sound Level Cooling Sound
Power
dBA 72.0 78.0 78.0
Sound
Pressure
dBA 54.0 57.0 58.0
Refrigerant Name R-410A
Charge kg 5.6 7.6 8.6
Control Expansion valve
Nr of Circuits 1 1 1
Refrigerant Oil Name Synthetic (ether) oil
Charged Volume l 1.7 1.6 + 1.7 + 2 1.6 + 1.7 + 2
Piping
connections
Liquid (OD) Type Flare connection
Diameter
(OD)
mm 9.5 9.5 9.5
Gas Type Flare connection Braze connection Braze connection
Diameter
(OD)
mm 15.9 19.1 22.2
Heat Insulation Both liquid and gas pipes
Max total length m 300 300 300
Capacity Control Method Inverter controlled
Capacity Control 14 to 100
Safety devices HPS
Fan motor driver overload protector
Inverter overload protector
PC board fuse Over current relay Over current relay
Standard
Accessories
Standard Accessories Installation and operation manual
Quantity 1 1 1
Standard Accessories - Connection pipes Connection pipes
Quantity - 3 3
Standard Accessories Additional refrigerant label
Quantity 1 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please
refer to sound level drawings.
Sound values are measured in a semi-anechoic room.
1-1 TECHNICAL SPECIFICATIONS RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B
Содержание
- Systems 1
- Technical data 1
- Capacity correction facto 2
- Capacity table 2
- Centre of gravity 2
- Cooling capacity tables 2
- Dimensional drawing 2
- Dimensional drawing centre of gravit 2
- Electrical specifications 2
- External connection diagram 2
- Fixation and foundation of units 2
- Installatio 2
- Operation rang 2
- Option 2
- Piping diagra 2
- Refrigerant pipe selection 2
- Service space 2
- Sound leve 2
- Sound power spectrums 2
- Sound pressure spectrums 2
- Specification 2
- Table of contents rxq5 10m9w1b 2
- Technical specifications 2
- Wiring diagra 2
- Wiring diagram 2
- 1 technical specifications 3
- Outdoor units vrv cooling only system rxq5 10m9w1b 3
- Specifications 3
- Vrvii systems outdoor units 2 3
- 1 technical specifications 4
- Outdoor units vrv cooling only system rxq5 10m9w1b 4
- Vrvii systems outdoor units 3 4
- 2 electrical specifications 5
- Outdoor units vrv cooling only system rxq5 10m9w1b 5
- Vrvii systems outdoor units 4 5
- Options 6
- Outdoor units vrv cooling only system rxq5 10m9w1b 6
- Vrvii systems outdoor units 5 6
- 1 cooling capacity tables 7
- Capacity tables 7
- Outdoor units vrv cooling only system rxq5 10m9w1b 7
- Vrvii systems outdoor units 6 7
- 1 cooling capacity tables 8
- Capacity tables 8
- 1 cooling capacity tables 9
- Capacity tables 9
- Outdoor units vrv cooling only system rxq5 10m9w1b 9
- Vrvii systems outdoor units 8 9
- 1 cooling capacity tables 10
- Capacity tables 10
- 1 cooling capacity tables 11
- Capacity tables 11
- Outdoor units vrv cooling only system rxq5 10m9w1b 11
- Vrvii systems outdoor units 10 11
- 1 cooling capacity tables 12
- Capacity tables 12
- Capacity correction factor 13
- Outdoor units vrv cooling only system rxq5 10m9w1b 13
- Rx y q5m 13
- Vrvii systems outdoor units 12 13
- Capacity correction factor 14
- Capacity correction factor 15
- Outdoor units vrv cooling only system rxq5 10m9w1b 15
- Rx y q10m 15
- Vrvii systems outdoor units 14 15
- 1 dimensional drawing 16
- Dimensional drawing centre of gravity 16
- 1 dimensional drawing 17
- Dimensional drawing centre of gravity 17
- 2 centre of gravity 18
- Dimensional drawing centre of gravity 18
- 2 centre of gravity 19
- Dimensional drawing centre of gravity 19
- Piping diagram 20
- Outdoor units vrv cooling only system rxq5 10m9w1b 21
- Piping diagram 21
- Vrvii systems outdoor units 20 21
- 1 wiring diagram 22
- Wiring diagram 22
- 1 wiring diagram 23
- Outdoor units vrv cooling only system rxq5 10m9w1b 23
- Vrvii systems outdoor units 22 23
- Wiring diagram 23
- 2 external connection diagram 24
- Wiring diagram 24
- 1 sound pressure spectrums 25
- Outdoor units vrv cooling only system rxq5 10m9w1b 25
- Sound level 25
- Vrvii systems outdoor units 24 25
- 2 sound power spectrums 26
- Sound level 26
- 1 service space 27
- Installation 27
- Outdoor units vrv cooling only system rxq5 10m9w1b 27
- Vrvii systems outdoor units 26 27
- 2 fixation and foundation of units 28
- Installation 28
- 3 refrigerant pipe selection 29
- Installation 29
- Outdoor units vrv cooling only system rxq5 10m9w1b 29
- Vrvii systems outdoor units 28 29
- 3 refrigerant pipe selection 30
- Installation 30
- Cooling 31
- Indoor temperature cwb 31
- Operation range 31
- Outdoor temperature cdb 31
- Range for pull down operation 31
- Eede05 2 06 2005 prepared in belgium by lannoo 32
- Specifications are subject to change without prior notice 32
- Systems 32
- Zandvoordestraat 300 b 8400 ostend belgium www daikineurope com 32
Похожие устройства
- Daikin RXQ8M9W1B Технические данные
- Daikin RXQ10M9W1B Технические данные
- Daikin RXQ5M9W1B Инструкция по монтажу
- Daikin RXQ8M9W1B Инструкция по монтажу
- Daikin RXQ10M9W1B Инструкция по монтажу
- Daikin RXQ5M9W1B Инструкция по эксплуатации
- Daikin RXQ8M9W1B Инструкция по эксплуатации
- Daikin RXQ10M9W1B Инструкция по эксплуатации
- Daikin RZP350MAY1 Технические данные
- Daikin RZP350MAY1 Руководство по вводу в эксплуатацию
- SilverStone SST-RM208 (V2.0) Инструкция по эксплуатации
- SilverStone SST-RM208 (V2.0) Технические характеристики
- SilverStone SST-RM208-RS01 Инструкция по эксплуатации
- SilverStone SST-RM208-RS01 Технические характеристики
- SilverStone RM212 Инструкция по эксплуатации
- SilverStone RM212 Технические характеристики
- SilverStone SST-RM212 Инструкция по эксплуатации
- SilverStone SST-RM212 Технические характеристики
- SilverStone SST-RM212-RS01 Инструкция по эксплуатации
- SilverStone SST-RM212-RS01 Технические характеристики